OCT wavenumber calibration with simple reference arm modification

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

  • Miroslav Zabic
  • Simon Hansert
  • Sonja Johannsmeier
  • Dag Heinemann
  • Alexander Heisterkamp
  • Tammo Ripken
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksOptical Coherence Imaging Techniques and Imaging in Scattering Media IV
Herausgeber (Verlag)OSA - The Optical Society
ISBN (elektronisch)9781557528209
PublikationsstatusVeröffentlicht - 9 Dez. 2021
Veranstaltung2021 European Conferences on Biomedical Optics, ECBO 2021 - Virtual, Online, Deutschland
Dauer: 20 Juni 202124 Juni 2021

Publikationsreihe

NameOptics InfoBase Conference Papers
Band11924

Abstract

FD-OCT systems with non-uniform wavenumber sampling require calibration and resampling routines to achieve optimal axial resolution. We present a simple calibration procedure and provide all necessary algorithmic components for wavenumber resampling.

ASJC Scopus Sachgebiete

Zitieren

OCT wavenumber calibration with simple reference arm modification. / Zabic, Miroslav; Hansert, Simon; Johannsmeier, Sonja et al.
Optical Coherence Imaging Techniques and Imaging in Scattering Media IV. OSA - The Optical Society, 2021. EW4A.5 (Optics InfoBase Conference Papers; Band 11924).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Zabic, M, Hansert, S, Johannsmeier, S, Heinemann, D, Heisterkamp, A & Ripken, T 2021, OCT wavenumber calibration with simple reference arm modification. in Optical Coherence Imaging Techniques and Imaging in Scattering Media IV., EW4A.5, Optics InfoBase Conference Papers, Bd. 11924, OSA - The Optical Society, 2021 European Conferences on Biomedical Optics, ECBO 2021, Virtual, Online, Deutschland, 20 Juni 2021. https://doi.org/10.1117/12.2616143, https://doi.org/10.15488/11355
Zabic, M., Hansert, S., Johannsmeier, S., Heinemann, D., Heisterkamp, A., & Ripken, T. (2021). OCT wavenumber calibration with simple reference arm modification. In Optical Coherence Imaging Techniques and Imaging in Scattering Media IV Artikel EW4A.5 (Optics InfoBase Conference Papers; Band 11924). OSA - The Optical Society. https://doi.org/10.1117/12.2616143, https://doi.org/10.15488/11355
Zabic M, Hansert S, Johannsmeier S, Heinemann D, Heisterkamp A, Ripken T. OCT wavenumber calibration with simple reference arm modification. in Optical Coherence Imaging Techniques and Imaging in Scattering Media IV. OSA - The Optical Society. 2021. EW4A.5. (Optics InfoBase Conference Papers). doi: 10.1117/12.2616143, 10.15488/11355
Zabic, Miroslav ; Hansert, Simon ; Johannsmeier, Sonja et al. / OCT wavenumber calibration with simple reference arm modification. Optical Coherence Imaging Techniques and Imaging in Scattering Media IV. OSA - The Optical Society, 2021. (Optics InfoBase Conference Papers).
Download
@inproceedings{def3dd66bc3c418abe6f8800cb258b80,
title = "OCT wavenumber calibration with simple reference arm modification",
abstract = "FD-OCT systems with non-uniform wavenumber sampling require calibration and resampling routines to achieve optimal axial resolution. We present a simple calibration procedure and provide all necessary algorithmic components for wavenumber resampling.",
author = "Miroslav Zabic and Simon Hansert and Sonja Johannsmeier and Dag Heinemann and Alexander Heisterkamp and Tammo Ripken",
note = "Funding Information: This work was partially funded by the European Regional Development Fund and the state of Lower Saxony as part of the project OPhonLas (EFRE-SER 2014-2020, 85007492).; 2021 European Conferences on Biomedical Optics, ECBO 2021 ; Conference date: 20-06-2021 Through 24-06-2021",
year = "2021",
month = dec,
day = "9",
doi = "10.1117/12.2616143",
language = "English",
series = "Optics InfoBase Conference Papers",
publisher = "OSA - The Optical Society",
booktitle = "Optical Coherence Imaging Techniques and Imaging in Scattering Media IV",
address = "United States",

}

Download

TY - GEN

T1 - OCT wavenumber calibration with simple reference arm modification

AU - Zabic, Miroslav

AU - Hansert, Simon

AU - Johannsmeier, Sonja

AU - Heinemann, Dag

AU - Heisterkamp, Alexander

AU - Ripken, Tammo

N1 - Funding Information: This work was partially funded by the European Regional Development Fund and the state of Lower Saxony as part of the project OPhonLas (EFRE-SER 2014-2020, 85007492).

PY - 2021/12/9

Y1 - 2021/12/9

N2 - FD-OCT systems with non-uniform wavenumber sampling require calibration and resampling routines to achieve optimal axial resolution. We present a simple calibration procedure and provide all necessary algorithmic components for wavenumber resampling.

AB - FD-OCT systems with non-uniform wavenumber sampling require calibration and resampling routines to achieve optimal axial resolution. We present a simple calibration procedure and provide all necessary algorithmic components for wavenumber resampling.

UR - http://www.scopus.com/inward/record.url?scp=85119405629&partnerID=8YFLogxK

U2 - 10.1117/12.2616143

DO - 10.1117/12.2616143

M3 - Conference contribution

AN - SCOPUS:85119405629

T3 - Optics InfoBase Conference Papers

BT - Optical Coherence Imaging Techniques and Imaging in Scattering Media IV

PB - OSA - The Optical Society

T2 - 2021 European Conferences on Biomedical Optics, ECBO 2021

Y2 - 20 June 2021 through 24 June 2021

ER -

Von denselben Autoren