Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment

Research output: Working paper/PreprintPreprint

Authors

Research Organisations

View graph of relations

Details

Original languageEnglish
Publication statusE-pub ahead of print - 11 Jul 2022

Abstract

Inertial measurement units (IMUs) are used in medical applications for many different purposes. However, an IMU's measurement accuracy can degrade over time, entailing re-calibration. In their 2014 paper, Tedaldi et al. presented an IMU calibration method that does not require external precision equipment or complex procedures. This allows end-users or personnel without expert knowledge of inertial measurement to re-calibrate the sensors by placing them in several suitable but not precisely defined orientations. In this work, we present several improvements to Tedaldi's method, both on the algorithmic level and the calibration procedure: adaptions for low noise accelerometers, a calibration helper object, and packet loss compensation for wireless calibration. We applied the modified calibration procedure to our custom-built IMU platform and verified the consistency of results across multiple calibration runs. In order to minimize the time needed for re-calibration, we analyzed how the calibration result accuracy degrades when fewer calibration orientations are used. We found that N=12 different orientations are sufficient to achieve a very good calibration, and more orientations yielded only marginal improvements. This is a significant improvement compared to the 37 to 50 orientations recommended by Tedaldi. Thus, we were reduced the time required to calibrate a single IMU from ca. 5 minutes to less than 2 minutes without sacrificing any meaningful calibration accuracy.

Keywords

    eess.SP

Cite this

Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment. / Webering, Fritz; Kleinjohann, Sarah; Stanislawski, Nils et al.
2022.

Research output: Working paper/PreprintPreprint

Webering F, Kleinjohann S, Stanislawski N, Blume H. Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment. 2022 Jul 11. Epub 2022 Jul 11. doi: 10.48550/arXiv.2207.04801, 10.15488/13696
Download
@techreport{b70ae7529cc14be5a20e8960202cf053,
title = "Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment",
abstract = "Inertial measurement units (IMUs) are used in medical applications for many different purposes. However, an IMU's measurement accuracy can degrade over time, entailing re-calibration. In their 2014 paper, Tedaldi et al. presented an IMU calibration method that does not require external precision equipment or complex procedures. This allows end-users or personnel without expert knowledge of inertial measurement to re-calibrate the sensors by placing them in several suitable but not precisely defined orientations. In this work, we present several improvements to Tedaldi's method, both on the algorithmic level and the calibration procedure: adaptions for low noise accelerometers, a calibration helper object, and packet loss compensation for wireless calibration. We applied the modified calibration procedure to our custom-built IMU platform and verified the consistency of results across multiple calibration runs. In order to minimize the time needed for re-calibration, we analyzed how the calibration result accuracy degrades when fewer calibration orientations are used. We found that N=12 different orientations are sufficient to achieve a very good calibration, and more orientations yielded only marginal improvements. This is a significant improvement compared to the 37 to 50 orientations recommended by Tedaldi. Thus, we were reduced the time required to calibrate a single IMU from ca. 5 minutes to less than 2 minutes without sacrificing any meaningful calibration accuracy.",
keywords = "eess.SP",
author = "Fritz Webering and Sarah Kleinjohann and Nils Stanislawski and Holger Blume",
note = "Submitted to BioCAS 2022",
year = "2022",
month = jul,
day = "11",
doi = "10.48550/arXiv.2207.04801",
language = "English",
type = "WorkingPaper",

}

Download

TY - UNPB

T1 - Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment

AU - Webering, Fritz

AU - Kleinjohann, Sarah

AU - Stanislawski, Nils

AU - Blume, Holger

N1 - Submitted to BioCAS 2022

PY - 2022/7/11

Y1 - 2022/7/11

N2 - Inertial measurement units (IMUs) are used in medical applications for many different purposes. However, an IMU's measurement accuracy can degrade over time, entailing re-calibration. In their 2014 paper, Tedaldi et al. presented an IMU calibration method that does not require external precision equipment or complex procedures. This allows end-users or personnel without expert knowledge of inertial measurement to re-calibrate the sensors by placing them in several suitable but not precisely defined orientations. In this work, we present several improvements to Tedaldi's method, both on the algorithmic level and the calibration procedure: adaptions for low noise accelerometers, a calibration helper object, and packet loss compensation for wireless calibration. We applied the modified calibration procedure to our custom-built IMU platform and verified the consistency of results across multiple calibration runs. In order to minimize the time needed for re-calibration, we analyzed how the calibration result accuracy degrades when fewer calibration orientations are used. We found that N=12 different orientations are sufficient to achieve a very good calibration, and more orientations yielded only marginal improvements. This is a significant improvement compared to the 37 to 50 orientations recommended by Tedaldi. Thus, we were reduced the time required to calibrate a single IMU from ca. 5 minutes to less than 2 minutes without sacrificing any meaningful calibration accuracy.

AB - Inertial measurement units (IMUs) are used in medical applications for many different purposes. However, an IMU's measurement accuracy can degrade over time, entailing re-calibration. In their 2014 paper, Tedaldi et al. presented an IMU calibration method that does not require external precision equipment or complex procedures. This allows end-users or personnel without expert knowledge of inertial measurement to re-calibrate the sensors by placing them in several suitable but not precisely defined orientations. In this work, we present several improvements to Tedaldi's method, both on the algorithmic level and the calibration procedure: adaptions for low noise accelerometers, a calibration helper object, and packet loss compensation for wireless calibration. We applied the modified calibration procedure to our custom-built IMU platform and verified the consistency of results across multiple calibration runs. In order to minimize the time needed for re-calibration, we analyzed how the calibration result accuracy degrades when fewer calibration orientations are used. We found that N=12 different orientations are sufficient to achieve a very good calibration, and more orientations yielded only marginal improvements. This is a significant improvement compared to the 37 to 50 orientations recommended by Tedaldi. Thus, we were reduced the time required to calibrate a single IMU from ca. 5 minutes to less than 2 minutes without sacrificing any meaningful calibration accuracy.

KW - eess.SP

U2 - 10.48550/arXiv.2207.04801

DO - 10.48550/arXiv.2207.04801

M3 - Preprint

BT - Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment

ER -

By the same author(s)