Residual Stresses from Incremental Hole Drilling Using Directly Deposited Thin Film Strain Gauges

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)701-713
Seitenumfang13
FachzeitschriftExperimental mechanics
Jahrgang62
Ausgabenummer4
Frühes Online-Datum14 Jan. 2022
PublikationsstatusVeröffentlicht - Apr. 2022

Abstract

Background: Commonly, polymer foil-based strain gauges are used for the incremental hole drilling method to obtain residual stress depth profiles. These polymer foil-based strain gauges are prone to errors due to application by glue. For example zero depth setting is thus often erroneous due to necessary removal of polymer foil and glue. This is resulting in wrong use of the calibration coefficients and depth resolution and thus leading to wrong calculations of the obtained residual stress depth profiles. Additionally common polymer foil-based sensors are limited in their application regarding e.g. exposure to high temperatures. Objective: This paper aims at a first step into the qualification of directly deposited thin film strain gauges for use with the incremental hole drilling method. With the directly deposited sensors, uncertainties regarding the determination of calibration coefficients and zero depth setting due to the absence of glue can be reduced to a minimum. Additionally, new areas of interest such as the investigation of thermally sprayed metallic layers can be addressed by the sensors due to their higher temperature resilience and their component inherent minimal thickness. Methods: For the first time, different layouts of directly deposited thin film strain gauges for residual stress measurements were manufactured on a stainless steel specimen. Strain measurements during incremental hole drilling using a bespoke hole drilling device were conducted. Residual stress depth profiles were calculated using the Integral method of the ASTM E837 standard. Afterwards, strain measurements with conventional polymer foil-based strain gauges during incremental hole drilling were conducted and residual stress depth profiles were calculated accordingly. Finally the obtained profiles were compared regarding characteristic values. Results: The residual stress depth profiles obtained from directly deposited strain gauges generally match the ones obtained from conventional polymer foil based strain gauges. With the novel strain gauges, zero depth setting is simplified due to the absence of glue and polymer foil. With the direct deposition, a wide variety of rosette designs is possible, enabling a more detailed evaluation of the strain field around the drilled hole. Conclusions: The comparative analysis of the obtained residual stress depth profiles shows the general feasibility of directly deposited strain gauges for residual stress measurements. Detailed investigations on uncertainty sources are still necessary.

ASJC Scopus Sachgebiete

Zitieren

Residual Stresses from Incremental Hole Drilling Using Directly Deposited Thin Film Strain Gauges. / Heikebrügge, S.; Ottermann, R.; Breidenstein, B. et al.
in: Experimental mechanics, Jahrgang 62, Nr. 4, 04.2022, S. 701-713.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Heikebrügge S, Ottermann R, Breidenstein B, Wurz MC, Dencker F. Residual Stresses from Incremental Hole Drilling Using Directly Deposited Thin Film Strain Gauges. Experimental mechanics. 2022 Apr;62(4):701-713. Epub 2022 Jan 14. doi: 10.1007/s11340-022-00822-0
Heikebrügge, S. ; Ottermann, R. ; Breidenstein, B. et al. / Residual Stresses from Incremental Hole Drilling Using Directly Deposited Thin Film Strain Gauges. in: Experimental mechanics. 2022 ; Jahrgang 62, Nr. 4. S. 701-713.
Download
@article{1629ab228bff421cba33629abc8492c2,
title = "Residual Stresses from Incremental Hole Drilling Using Directly Deposited Thin Film Strain Gauges",
abstract = "Background: Commonly, polymer foil-based strain gauges are used for the incremental hole drilling method to obtain residual stress depth profiles. These polymer foil-based strain gauges are prone to errors due to application by glue. For example zero depth setting is thus often erroneous due to necessary removal of polymer foil and glue. This is resulting in wrong use of the calibration coefficients and depth resolution and thus leading to wrong calculations of the obtained residual stress depth profiles. Additionally common polymer foil-based sensors are limited in their application regarding e.g. exposure to high temperatures. Objective: This paper aims at a first step into the qualification of directly deposited thin film strain gauges for use with the incremental hole drilling method. With the directly deposited sensors, uncertainties regarding the determination of calibration coefficients and zero depth setting due to the absence of glue can be reduced to a minimum. Additionally, new areas of interest such as the investigation of thermally sprayed metallic layers can be addressed by the sensors due to their higher temperature resilience and their component inherent minimal thickness. Methods: For the first time, different layouts of directly deposited thin film strain gauges for residual stress measurements were manufactured on a stainless steel specimen. Strain measurements during incremental hole drilling using a bespoke hole drilling device were conducted. Residual stress depth profiles were calculated using the Integral method of the ASTM E837 standard. Afterwards, strain measurements with conventional polymer foil-based strain gauges during incremental hole drilling were conducted and residual stress depth profiles were calculated accordingly. Finally the obtained profiles were compared regarding characteristic values. Results: The residual stress depth profiles obtained from directly deposited strain gauges generally match the ones obtained from conventional polymer foil based strain gauges. With the novel strain gauges, zero depth setting is simplified due to the absence of glue and polymer foil. With the direct deposition, a wide variety of rosette designs is possible, enabling a more detailed evaluation of the strain field around the drilled hole. Conclusions: The comparative analysis of the obtained residual stress depth profiles shows the general feasibility of directly deposited strain gauges for residual stress measurements. Detailed investigations on uncertainty sources are still necessary.",
keywords = "Direct deposition, Incremental hole-drilling method, Residual stress, Sputtering, Temperature sensors, Thin-film strain gauges",
author = "S. Heikebr{\"u}gge and R. Ottermann and B. Breidenstein and Wurz, {M. C.} and F. Dencker",
note = "Funding Information: The authors thank the German Federation of Industrial Research Associations (AiF) for the financial support of the project “Deep rolled welds – Increased fatigue strength of welded joints in wind energy by deep rolling”, grant number 20626/N. ",
year = "2022",
month = apr,
doi = "10.1007/s11340-022-00822-0",
language = "English",
volume = "62",
pages = "701--713",
journal = "Experimental mechanics",
issn = "0014-4851",
publisher = "Springer New York",
number = "4",

}

Download

TY - JOUR

T1 - Residual Stresses from Incremental Hole Drilling Using Directly Deposited Thin Film Strain Gauges

AU - Heikebrügge, S.

AU - Ottermann, R.

AU - Breidenstein, B.

AU - Wurz, M. C.

AU - Dencker, F.

N1 - Funding Information: The authors thank the German Federation of Industrial Research Associations (AiF) for the financial support of the project “Deep rolled welds – Increased fatigue strength of welded joints in wind energy by deep rolling”, grant number 20626/N.

PY - 2022/4

Y1 - 2022/4

N2 - Background: Commonly, polymer foil-based strain gauges are used for the incremental hole drilling method to obtain residual stress depth profiles. These polymer foil-based strain gauges are prone to errors due to application by glue. For example zero depth setting is thus often erroneous due to necessary removal of polymer foil and glue. This is resulting in wrong use of the calibration coefficients and depth resolution and thus leading to wrong calculations of the obtained residual stress depth profiles. Additionally common polymer foil-based sensors are limited in their application regarding e.g. exposure to high temperatures. Objective: This paper aims at a first step into the qualification of directly deposited thin film strain gauges for use with the incremental hole drilling method. With the directly deposited sensors, uncertainties regarding the determination of calibration coefficients and zero depth setting due to the absence of glue can be reduced to a minimum. Additionally, new areas of interest such as the investigation of thermally sprayed metallic layers can be addressed by the sensors due to their higher temperature resilience and their component inherent minimal thickness. Methods: For the first time, different layouts of directly deposited thin film strain gauges for residual stress measurements were manufactured on a stainless steel specimen. Strain measurements during incremental hole drilling using a bespoke hole drilling device were conducted. Residual stress depth profiles were calculated using the Integral method of the ASTM E837 standard. Afterwards, strain measurements with conventional polymer foil-based strain gauges during incremental hole drilling were conducted and residual stress depth profiles were calculated accordingly. Finally the obtained profiles were compared regarding characteristic values. Results: The residual stress depth profiles obtained from directly deposited strain gauges generally match the ones obtained from conventional polymer foil based strain gauges. With the novel strain gauges, zero depth setting is simplified due to the absence of glue and polymer foil. With the direct deposition, a wide variety of rosette designs is possible, enabling a more detailed evaluation of the strain field around the drilled hole. Conclusions: The comparative analysis of the obtained residual stress depth profiles shows the general feasibility of directly deposited strain gauges for residual stress measurements. Detailed investigations on uncertainty sources are still necessary.

AB - Background: Commonly, polymer foil-based strain gauges are used for the incremental hole drilling method to obtain residual stress depth profiles. These polymer foil-based strain gauges are prone to errors due to application by glue. For example zero depth setting is thus often erroneous due to necessary removal of polymer foil and glue. This is resulting in wrong use of the calibration coefficients and depth resolution and thus leading to wrong calculations of the obtained residual stress depth profiles. Additionally common polymer foil-based sensors are limited in their application regarding e.g. exposure to high temperatures. Objective: This paper aims at a first step into the qualification of directly deposited thin film strain gauges for use with the incremental hole drilling method. With the directly deposited sensors, uncertainties regarding the determination of calibration coefficients and zero depth setting due to the absence of glue can be reduced to a minimum. Additionally, new areas of interest such as the investigation of thermally sprayed metallic layers can be addressed by the sensors due to their higher temperature resilience and their component inherent minimal thickness. Methods: For the first time, different layouts of directly deposited thin film strain gauges for residual stress measurements were manufactured on a stainless steel specimen. Strain measurements during incremental hole drilling using a bespoke hole drilling device were conducted. Residual stress depth profiles were calculated using the Integral method of the ASTM E837 standard. Afterwards, strain measurements with conventional polymer foil-based strain gauges during incremental hole drilling were conducted and residual stress depth profiles were calculated accordingly. Finally the obtained profiles were compared regarding characteristic values. Results: The residual stress depth profiles obtained from directly deposited strain gauges generally match the ones obtained from conventional polymer foil based strain gauges. With the novel strain gauges, zero depth setting is simplified due to the absence of glue and polymer foil. With the direct deposition, a wide variety of rosette designs is possible, enabling a more detailed evaluation of the strain field around the drilled hole. Conclusions: The comparative analysis of the obtained residual stress depth profiles shows the general feasibility of directly deposited strain gauges for residual stress measurements. Detailed investigations on uncertainty sources are still necessary.

KW - Direct deposition

KW - Incremental hole-drilling method

KW - Residual stress

KW - Sputtering

KW - Temperature sensors

KW - Thin-film strain gauges

UR - http://www.scopus.com/inward/record.url?scp=85123077500&partnerID=8YFLogxK

U2 - 10.1007/s11340-022-00822-0

DO - 10.1007/s11340-022-00822-0

M3 - Article

AN - SCOPUS:85123077500

VL - 62

SP - 701

EP - 713

JO - Experimental mechanics

JF - Experimental mechanics

SN - 0014-4851

IS - 4

ER -

Von denselben Autoren