Current Interrupt Technique to Fully Characterize PEMWE Cells

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Externe Organisationen

  • Siemens AG
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer034509
Seitenumfang12
FachzeitschriftJournal of the Electrochemical Society
Jahrgang171
Ausgabenummer3
PublikationsstatusVeröffentlicht - 18 März 2024

Abstract

It is common practice to characterize cells in polymer electrolyte membrane water electrolysis (PEMWE) using electrochemical impedance spectroscopy (EIS) and Tafel analysis, which require special equipment and operation procedures. Additionally, these techniques are not suitable for large industrial size cells with very low impedances. We present a simpler approach based on a novel evaluation of the current interrupt (CI) technique. The CI technique utilizes the voltage response after an instantaneous drop of electric current to identify the ohmic resistance R Ω, charge transfer resistance R ct and double-layer capacity C dl in a simplified equivalent circuit (EC) of the cell. A direct link to results of typical EIS and Tafel analysis can be defined by using the improved CI method which considers a non-linear activation resistance instead of a constant charge transfer resistance. Thereby, access to equivalent information as the established standard method is granted, while being applicable to all cell and stack sizes without requiring special equipment (e.g. impedance spectrometer). The agreement with experimental data is significantly improved over the assumption of a constant charge transfer coefficient. Consistency of the proposed interpretation with explicit EIS and Tafel analysis is demonstrated and options for industrial application of the evaluation scheme are discussed.

ASJC Scopus Sachgebiete

Ziele für nachhaltige Entwicklung

Zitieren

Current Interrupt Technique to Fully Characterize PEMWE Cells. / Krenz, Tobias; Gottschalk, Torben; Helmers, Lennard et al.
in: Journal of the Electrochemical Society, Jahrgang 171, Nr. 3, 034509, 18.03.2024.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Krenz T, Gottschalk T, Helmers L, Trinke P, Bensmann B, Hanke-Rauschenbach R. Current Interrupt Technique to Fully Characterize PEMWE Cells. Journal of the Electrochemical Society. 2024 Mär 18;171(3):034509. doi: 10.1149/1945-7111/ad3057
Krenz, Tobias ; Gottschalk, Torben ; Helmers, Lennard et al. / Current Interrupt Technique to Fully Characterize PEMWE Cells. in: Journal of the Electrochemical Society. 2024 ; Jahrgang 171, Nr. 3.
Download
@article{921e842b4a1743ba954edd72e92fc8ba,
title = "Current Interrupt Technique to Fully Characterize PEMWE Cells",
abstract = "It is common practice to characterize cells in polymer electrolyte membrane water electrolysis (PEMWE) using electrochemical impedance spectroscopy (EIS) and Tafel analysis, which require special equipment and operation procedures. Additionally, these techniques are not suitable for large industrial size cells with very low impedances. We present a simpler approach based on a novel evaluation of the current interrupt (CI) technique. The CI technique utilizes the voltage response after an instantaneous drop of electric current to identify the ohmic resistance R Ω, charge transfer resistance R ct and double-layer capacity C dl in a simplified equivalent circuit (EC) of the cell. A direct link to results of typical EIS and Tafel analysis can be defined by using the improved CI method which considers a non-linear activation resistance instead of a constant charge transfer resistance. Thereby, access to equivalent information as the established standard method is granted, while being applicable to all cell and stack sizes without requiring special equipment (e.g. impedance spectrometer). The agreement with experimental data is significantly improved over the assumption of a constant charge transfer coefficient. Consistency of the proposed interpretation with explicit EIS and Tafel analysis is demonstrated and options for industrial application of the evaluation scheme are discussed.",
keywords = "electrochemical engineering, energy conversion, Fuel Cells—PEM, industrial electrolysis",
author = "Tobias Krenz and Torben Gottschalk and Lennard Helmers and Patrick Trinke and Boris Bensmann and Richard Hanke-Rauschenbach",
year = "2024",
month = mar,
day = "18",
doi = "10.1149/1945-7111/ad3057",
language = "English",
volume = "171",
journal = "Journal of the Electrochemical Society",
issn = "0013-4651",
publisher = "Electrochemical Society, Inc.",
number = "3",

}

Download

TY - JOUR

T1 - Current Interrupt Technique to Fully Characterize PEMWE Cells

AU - Krenz, Tobias

AU - Gottschalk, Torben

AU - Helmers, Lennard

AU - Trinke, Patrick

AU - Bensmann, Boris

AU - Hanke-Rauschenbach, Richard

PY - 2024/3/18

Y1 - 2024/3/18

N2 - It is common practice to characterize cells in polymer electrolyte membrane water electrolysis (PEMWE) using electrochemical impedance spectroscopy (EIS) and Tafel analysis, which require special equipment and operation procedures. Additionally, these techniques are not suitable for large industrial size cells with very low impedances. We present a simpler approach based on a novel evaluation of the current interrupt (CI) technique. The CI technique utilizes the voltage response after an instantaneous drop of electric current to identify the ohmic resistance R Ω, charge transfer resistance R ct and double-layer capacity C dl in a simplified equivalent circuit (EC) of the cell. A direct link to results of typical EIS and Tafel analysis can be defined by using the improved CI method which considers a non-linear activation resistance instead of a constant charge transfer resistance. Thereby, access to equivalent information as the established standard method is granted, while being applicable to all cell and stack sizes without requiring special equipment (e.g. impedance spectrometer). The agreement with experimental data is significantly improved over the assumption of a constant charge transfer coefficient. Consistency of the proposed interpretation with explicit EIS and Tafel analysis is demonstrated and options for industrial application of the evaluation scheme are discussed.

AB - It is common practice to characterize cells in polymer electrolyte membrane water electrolysis (PEMWE) using electrochemical impedance spectroscopy (EIS) and Tafel analysis, which require special equipment and operation procedures. Additionally, these techniques are not suitable for large industrial size cells with very low impedances. We present a simpler approach based on a novel evaluation of the current interrupt (CI) technique. The CI technique utilizes the voltage response after an instantaneous drop of electric current to identify the ohmic resistance R Ω, charge transfer resistance R ct and double-layer capacity C dl in a simplified equivalent circuit (EC) of the cell. A direct link to results of typical EIS and Tafel analysis can be defined by using the improved CI method which considers a non-linear activation resistance instead of a constant charge transfer resistance. Thereby, access to equivalent information as the established standard method is granted, while being applicable to all cell and stack sizes without requiring special equipment (e.g. impedance spectrometer). The agreement with experimental data is significantly improved over the assumption of a constant charge transfer coefficient. Consistency of the proposed interpretation with explicit EIS and Tafel analysis is demonstrated and options for industrial application of the evaluation scheme are discussed.

KW - electrochemical engineering

KW - energy conversion

KW - Fuel Cells—PEM

KW - industrial electrolysis

UR - http://www.scopus.com/inward/record.url?scp=85188128052&partnerID=8YFLogxK

U2 - 10.1149/1945-7111/ad3057

DO - 10.1149/1945-7111/ad3057

M3 - Article

AN - SCOPUS:85188128052

VL - 171

JO - Journal of the Electrochemical Society

JF - Journal of the Electrochemical Society

SN - 0013-4651

IS - 3

M1 - 034509

ER -

Von denselben Autoren