Determination of phase center corrections for Galileo signals

Research output: Contribution to conferencePosterResearch

Research Organisations

View graph of relations

Details

Original languageEnglish
Number of pages1
Publication statusPublished - 2019
Event7th International Colloquium on Scientific and Fundamental Aspects of GNSS - ETH Zürich, Zürich, Switzerland
Duration: 4 Sept 20196 Sept 2019

Conference

Conference7th International Colloquium on Scientific and Fundamental Aspects of GNSS
Country/TerritorySwitzerland
CityZürich
Period4 Sept 20196 Sept 2019

Abstract

GNSS are widely used for positioning, navigation and timing (PVT). The quality of results depends on the antenna in use and the capability to take antenna specific effects into account. The most prominent corrections are the direction dependent phase center corrections (PCC), which include corrections for the phase center offset (PCO) and the phase center variations (PCV). These corrections range between a few up to several millimeters for carrierphase observations and up to some decimeters for code observations. In addition, the magnitude of the error depends on the used antenna type and can differ even for different antennas of the same type and manufacturer. The frequency-dependent PCC are either determined in an anechoic chamber or in the field using a robot (so-called absolute field calibration). Both methods have their advantages and drawbacks. In the Antenna Exchange Format (ANTEX) from the International GNSS Service (IGS), which is widely used, currently only PCC for L1- and L2 frequencies for GPS and GLONASS are officially published. Absolute field calibrations values for new signals like Galileo or GPS L5 are missing. Only some chamber calibration results are available in the European Permanent Network (EPN). The Institute für Erdmessung (IfE) is one of the the IGS accepted absolute field calibration institutions and provides PCC using the so-called Hannover-Concept. In this approach a robot is used to precisely rotate and tilt the antenna under test. This concepts has now been extended to an experimental approach. The PCC of new signals are estimated in post-processing as spherical harmonics using time differenced single differences. First results show both – a high repeatability of the estimated pattern and an improvement on the observation domain. In this contribution the theoretical background as well as the extended concept are described. Moreover, patterns for Galileo signals and GPS L5 will be shown and discussed. After a short introduction into the method and the extended Hannover-Concept the robot model and the adjustment concept will be presented. The contribution will show that the estimation of PCC for Galileo signals is feasible with the developed method. This can be described by the root mean square (RMS) of differential pattern (of different calibrations). This indicator for the repeatability show RMS values for the EL1X signal under 0.6 mm for the NOV703GGG antenna and under 0.4 mm for the LEIAR25.R3. The RMS for the EL5X signal is maximal 0.6 mm for the NOV703GGG or 0.65 mm for the LEIAR25.R3. Furthermore, the obtained patterns will be presented and discussed for several antennas typical to IGS stations. For instance the PCV of the LEIAR25.R3 show values in a range of -4 to 7 mm for the EL1X frequency, whereas the Up-component of the PCO is approximately 60 mm. If these PCC are taken into account, the RMS of the single differences (SD) of a short baseline, common clock experiment at the Physikalisch-Technische Bundesanstalt (PTB) can be improved.

Cite this

Determination of phase center corrections for Galileo signals. / Kröger, Johannes; Breva, Yannick; Kersten, Tobias et al.
2019. Poster session presented at 7th International Colloquium on Scientific and Fundamental Aspects of GNSS, Zürich, Switzerland.

Research output: Contribution to conferencePosterResearch

Kröger, J, Breva, Y, Kersten, T & Schön, S 2019, 'Determination of phase center corrections for Galileo signals', 7th International Colloquium on Scientific and Fundamental Aspects of GNSS, Zürich, Switzerland, 4 Sept 2019 - 6 Sept 2019. https://doi.org/10.15488/5239
Kröger, J., Breva, Y., Kersten, T., & Schön, S. (2019). Determination of phase center corrections for Galileo signals. Poster session presented at 7th International Colloquium on Scientific and Fundamental Aspects of GNSS, Zürich, Switzerland. https://doi.org/10.15488/5239
Kröger J, Breva Y, Kersten T, Schön S. Determination of phase center corrections for Galileo signals. 2019. Poster session presented at 7th International Colloquium on Scientific and Fundamental Aspects of GNSS, Zürich, Switzerland. doi: 10.15488/5239
Kröger, Johannes ; Breva, Yannick ; Kersten, Tobias et al. / Determination of phase center corrections for Galileo signals. Poster session presented at 7th International Colloquium on Scientific and Fundamental Aspects of GNSS, Zürich, Switzerland.1 p.
Download
@conference{135064180d1c491b9f37884a1d6a2638,
title = "Determination of phase center corrections for Galileo signals",
abstract = "GNSS are widely used for positioning, navigation and timing (PVT). The quality of results depends on the antenna in use and the capability to take antenna specific effects into account. The most prominent corrections are the direction dependent phase center corrections (PCC), which include corrections for the phase center offset (PCO) and the phase center variations (PCV). These corrections range between a few up to several millimeters for carrierphase observations and up to some decimeters for code observations. In addition, the magnitude of the error depends on the used antenna type and can differ even for different antennas of the same type and manufacturer. The frequency-dependent PCC are either determined in an anechoic chamber or in the field using a robot (so-called absolute field calibration). Both methods have their advantages and drawbacks. In the Antenna Exchange Format (ANTEX) from the International GNSS Service (IGS), which is widely used, currently only PCC for L1- and L2 frequencies for GPS and GLONASS are officially published. Absolute field calibrations values for new signals like Galileo or GPS L5 are missing. Only some chamber calibration results are available in the European Permanent Network (EPN). The Institute f{\"u}r Erdmessung (IfE) is one of the the IGS accepted absolute field calibration institutions and provides PCC using the so-called Hannover-Concept. In this approach a robot is used to precisely rotate and tilt the antenna under test. This concepts has now been extended to an experimental approach. The PCC of new signals are estimated in post-processing as spherical harmonics using time differenced single differences. First results show both – a high repeatability of the estimated pattern and an improvement on the observation domain. In this contribution the theoretical background as well as the extended concept are described. Moreover, patterns for Galileo signals and GPS L5 will be shown and discussed. After a short introduction into the method and the extended Hannover-Concept the robot model and the adjustment concept will be presented. The contribution will show that the estimation of PCC for Galileo signals is feasible with the developed method. This can be described by the root mean square (RMS) of differential pattern (of different calibrations). This indicator for the repeatability show RMS values for the EL1X signal under 0.6 mm for the NOV703GGG antenna and under 0.4 mm for the LEIAR25.R3. The RMS for the EL5X signal is maximal 0.6 mm for the NOV703GGG or 0.65 mm for the LEIAR25.R3. Furthermore, the obtained patterns will be presented and discussed for several antennas typical to IGS stations. For instance the PCV of the LEIAR25.R3 show values in a range of -4 to 7 mm for the EL1X frequency, whereas the Up-component of the PCO is approximately 60 mm. If these PCC are taken into account, the RMS of the single differences (SD) of a short baseline, common clock experiment at the Physikalisch-Technische Bundesanstalt (PTB) can be improved.",
author = "Johannes Kr{\"o}ger and Yannick Breva and Tobias Kersten and Steffen Sch{\"o}n",
year = "2019",
doi = "10.15488/5239",
language = "English",
note = "7th International Colloquium on Scientific and Fundamental Aspects of GNSS ; Conference date: 04-09-2019 Through 06-09-2019",

}

Download

TY - CONF

T1 - Determination of phase center corrections for Galileo signals

AU - Kröger, Johannes

AU - Breva, Yannick

AU - Kersten, Tobias

AU - Schön, Steffen

PY - 2019

Y1 - 2019

N2 - GNSS are widely used for positioning, navigation and timing (PVT). The quality of results depends on the antenna in use and the capability to take antenna specific effects into account. The most prominent corrections are the direction dependent phase center corrections (PCC), which include corrections for the phase center offset (PCO) and the phase center variations (PCV). These corrections range between a few up to several millimeters for carrierphase observations and up to some decimeters for code observations. In addition, the magnitude of the error depends on the used antenna type and can differ even for different antennas of the same type and manufacturer. The frequency-dependent PCC are either determined in an anechoic chamber or in the field using a robot (so-called absolute field calibration). Both methods have their advantages and drawbacks. In the Antenna Exchange Format (ANTEX) from the International GNSS Service (IGS), which is widely used, currently only PCC for L1- and L2 frequencies for GPS and GLONASS are officially published. Absolute field calibrations values for new signals like Galileo or GPS L5 are missing. Only some chamber calibration results are available in the European Permanent Network (EPN). The Institute für Erdmessung (IfE) is one of the the IGS accepted absolute field calibration institutions and provides PCC using the so-called Hannover-Concept. In this approach a robot is used to precisely rotate and tilt the antenna under test. This concepts has now been extended to an experimental approach. The PCC of new signals are estimated in post-processing as spherical harmonics using time differenced single differences. First results show both – a high repeatability of the estimated pattern and an improvement on the observation domain. In this contribution the theoretical background as well as the extended concept are described. Moreover, patterns for Galileo signals and GPS L5 will be shown and discussed. After a short introduction into the method and the extended Hannover-Concept the robot model and the adjustment concept will be presented. The contribution will show that the estimation of PCC for Galileo signals is feasible with the developed method. This can be described by the root mean square (RMS) of differential pattern (of different calibrations). This indicator for the repeatability show RMS values for the EL1X signal under 0.6 mm for the NOV703GGG antenna and under 0.4 mm for the LEIAR25.R3. The RMS for the EL5X signal is maximal 0.6 mm for the NOV703GGG or 0.65 mm for the LEIAR25.R3. Furthermore, the obtained patterns will be presented and discussed for several antennas typical to IGS stations. For instance the PCV of the LEIAR25.R3 show values in a range of -4 to 7 mm for the EL1X frequency, whereas the Up-component of the PCO is approximately 60 mm. If these PCC are taken into account, the RMS of the single differences (SD) of a short baseline, common clock experiment at the Physikalisch-Technische Bundesanstalt (PTB) can be improved.

AB - GNSS are widely used for positioning, navigation and timing (PVT). The quality of results depends on the antenna in use and the capability to take antenna specific effects into account. The most prominent corrections are the direction dependent phase center corrections (PCC), which include corrections for the phase center offset (PCO) and the phase center variations (PCV). These corrections range between a few up to several millimeters for carrierphase observations and up to some decimeters for code observations. In addition, the magnitude of the error depends on the used antenna type and can differ even for different antennas of the same type and manufacturer. The frequency-dependent PCC are either determined in an anechoic chamber or in the field using a robot (so-called absolute field calibration). Both methods have their advantages and drawbacks. In the Antenna Exchange Format (ANTEX) from the International GNSS Service (IGS), which is widely used, currently only PCC for L1- and L2 frequencies for GPS and GLONASS are officially published. Absolute field calibrations values for new signals like Galileo or GPS L5 are missing. Only some chamber calibration results are available in the European Permanent Network (EPN). The Institute für Erdmessung (IfE) is one of the the IGS accepted absolute field calibration institutions and provides PCC using the so-called Hannover-Concept. In this approach a robot is used to precisely rotate and tilt the antenna under test. This concepts has now been extended to an experimental approach. The PCC of new signals are estimated in post-processing as spherical harmonics using time differenced single differences. First results show both – a high repeatability of the estimated pattern and an improvement on the observation domain. In this contribution the theoretical background as well as the extended concept are described. Moreover, patterns for Galileo signals and GPS L5 will be shown and discussed. After a short introduction into the method and the extended Hannover-Concept the robot model and the adjustment concept will be presented. The contribution will show that the estimation of PCC for Galileo signals is feasible with the developed method. This can be described by the root mean square (RMS) of differential pattern (of different calibrations). This indicator for the repeatability show RMS values for the EL1X signal under 0.6 mm for the NOV703GGG antenna and under 0.4 mm for the LEIAR25.R3. The RMS for the EL5X signal is maximal 0.6 mm for the NOV703GGG or 0.65 mm for the LEIAR25.R3. Furthermore, the obtained patterns will be presented and discussed for several antennas typical to IGS stations. For instance the PCV of the LEIAR25.R3 show values in a range of -4 to 7 mm for the EL1X frequency, whereas the Up-component of the PCO is approximately 60 mm. If these PCC are taken into account, the RMS of the single differences (SD) of a short baseline, common clock experiment at the Physikalisch-Technische Bundesanstalt (PTB) can be improved.

U2 - 10.15488/5239

DO - 10.15488/5239

M3 - Poster

T2 - 7th International Colloquium on Scientific and Fundamental Aspects of GNSS

Y2 - 4 September 2019 through 6 September 2019

ER -