Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 272-275 |
Seitenumfang | 4 |
Fachzeitschrift | International Association of Geodesy Symposia |
Jahrgang | 129 |
Publikationsstatus | Veröffentlicht - Sept. 2005 |
Abstract
The results of an international comparison of absolute gravimeters held in Walferdange Luxembourg in November 2003 are presented. The absolute meters agreed with one another with a standard deviation of less than 2 μ Gal (1 Gal = 1 cm/s2)(if we exclude one prototype instrument from the analysis). For the first time, the ability of the operators was put to the test. The comparison indicates that the errors due to the operator are less than 1 μGal, i.e. within the observational errors.
ASJC Scopus Sachgebiete
- Erdkunde und Planetologie (insg.)
- Computer in den Geowissenschaften
- Erdkunde und Planetologie (insg.)
- Geophysik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: International Association of Geodesy Symposia, Jahrgang 129, 09.2005, S. 272-275.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Results of the international comparison of absolute gravimeters in walferdange (Luxembourg) of November 2003
AU - Francis, Olivier
AU - van Dam, Tonie
AU - Amalvict, M.
AU - de Sousa, M. Andrade
AU - Bilker, M.
AU - Billson, R.
AU - D'Agostino, G.
AU - Desogus, S.
AU - Falk, R.
AU - Germak, A.
AU - Gitlein, O.
AU - Jonhson, D.
AU - Klopping, F.
AU - Kostelecky, J.
AU - Luck, B.
AU - Mäkinen, J.
AU - McLaughlin, D.
AU - Nunez, E.
AU - Origlia, C.
AU - Palinkas, V.
AU - Richard, P.
AU - Rodriguez, E.
AU - Ruess, D.
AU - Schmerge, D.
AU - Thies, S.
AU - Timmen, L.
AU - Van Camp, M.
AU - van Westrum, D.
AU - Wilmes, H.
PY - 2005/9
Y1 - 2005/9
N2 - The results of an international comparison of absolute gravimeters held in Walferdange Luxembourg in November 2003 are presented. The absolute meters agreed with one another with a standard deviation of less than 2 μ Gal (1 Gal = 1 cm/s2)(if we exclude one prototype instrument from the analysis). For the first time, the ability of the operators was put to the test. The comparison indicates that the errors due to the operator are less than 1 μGal, i.e. within the observational errors.
AB - The results of an international comparison of absolute gravimeters held in Walferdange Luxembourg in November 2003 are presented. The absolute meters agreed with one another with a standard deviation of less than 2 μ Gal (1 Gal = 1 cm/s2)(if we exclude one prototype instrument from the analysis). For the first time, the ability of the operators was put to the test. The comparison indicates that the errors due to the operator are less than 1 μGal, i.e. within the observational errors.
KW - Superconducting gravimeter
KW - Absolute Gravimeter
KW - Vertical gravity gradients
KW - Protoype Instrument
KW - Continental Water Storage
UR - http://www.scopus.com/inward/record.url?scp=84897095305&partnerID=8YFLogxK
U2 - 10.1007/3-540-26932-0_47
DO - 10.1007/3-540-26932-0_47
M3 - Article
AN - SCOPUS:84897095305
VL - 129
SP - 272
EP - 275
JO - International Association of Geodesy Symposia
JF - International Association of Geodesy Symposia
SN - 0939-9585
ER -