Abstract
FD-OCT systems with non-uniform wavenumber sampling require calibration and resampling routines to achieve optimal axial resolution. We present a simple calibration procedure and provide all necessary algorithmic components for wavenumber resampling.
ASJC Scopus Sachgebiete
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
- Physik und Astronomie (insg.)
- Atom- und Molekularphysik sowie Optik
- Werkstoffwissenschaften (insg.)
- Biomaterialien
- Medizin (insg.)
- Radiologie, Nuklearmedizin und Bildgebung
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
Optical Coherence Imaging Techniques and Imaging in Scattering Media IV. Hrsg. / Benjamin J. Vakoc; Maciej Wojtkowski; Yoshiaki Yasuno. SPIE, 2021. 119241L (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Band 11924).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - OCT wavenumber calibration with simple reference arm modification
AU - Zabic, Miroslav
AU - Hansert, Simon
AU - Johannsmeier, Sonja
AU - Heinemann, Dag
AU - Heisterkamp, Alexander
AU - Ripken, Tammo
N1 - Funding Information: This work was partially funded by the European Regional Development Fund and the state of Lower Saxony as part of the project OPhonLas (EFRE-SER 2014-2020, 85007492).
PY - 2021/12/9
Y1 - 2021/12/9
N2 - FD-OCT systems with non-uniform wavenumber sampling require calibration and resampling routines to achieve optimal axial resolution. We present a simple calibration procedure and provide all necessary algorithmic components for wavenumber resampling.
AB - FD-OCT systems with non-uniform wavenumber sampling require calibration and resampling routines to achieve optimal axial resolution. We present a simple calibration procedure and provide all necessary algorithmic components for wavenumber resampling.
UR - http://www.scopus.com/inward/record.url?scp=85122932446&partnerID=8YFLogxK
U2 - 10.1117/12.2616143
DO - 10.1117/12.2616143
M3 - Conference contribution
AN - SCOPUS:85122932446
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Optical Coherence Imaging Techniques and Imaging in Scattering Media IV
A2 - Vakoc, Benjamin J.
A2 - Wojtkowski, Maciej
A2 - Yasuno, Yoshiaki
PB - SPIE
T2 - Optical Coherence Imaging Techniques and Imaging in Scattering Media IV 2021
Y2 - 20 June 2021 through 24 June 2021
ER -