Establishment of a Perfusion Process with Antibody-Producing CHO Cells Using a 3D-Printed Microfluidic Spiral Separator with Web-Based Flow Control

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Organisationseinheiten

Externe Organisationen

  • Universität Augsburg
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer656
FachzeitschriftBioengineering
Jahrgang10
Ausgabenummer6
Frühes Online-Datum28 Mai 2023
PublikationsstatusVeröffentlicht - Juni 2023

Abstract

Monoclonal antibodies are increasingly dominating the market for human therapeutic and diagnostic agents. For this reason, continuous methods—such as perfusion processes—are being explored and optimized in an ongoing effort to increase product yields. Unfortunately, many established cell retention devices—such as tangential flow filtration—rely on membranes that are prone to clogging, fouling, and undesirable product retention at high cell densities. To circumvent these problems, in this work, we have developed a 3D-printed microfluidic spiral separator for cell retention, which can readily be adapted and replaced according to process conditions (i.e., a plug-and-play system) due to the fast and flexible 3D printing technique. In addition, this system was also expanded to include automatic flushing, web-based control, and notification via a cellphone application. This set-up constitutes a proof of concept that was successful at inducing a stable process operation at a viable cell concentration of 10–17 × 106 cells/mL in a hybrid mode (with alternating cell retention and cell bleed phases) while significantly reducing both shear stress and channel blockage. In addition to increasing efficiency to nearly 100%, this microfluidic device also improved production conditions by successfully separating dead cells and cell debris and increasing cell viability within the bioreactor.

ASJC Scopus Sachgebiete

Zitieren

Establishment of a Perfusion Process with Antibody-Producing CHO Cells Using a 3D-Printed Microfluidic Spiral Separator with Web-Based Flow Control. / Schellenberg, Jana; Dehne, Michaela; Lange, Ferdinand et al.
in: Bioengineering, Jahrgang 10, Nr. 6, 656, 06.2023.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Schellenberg J, Dehne M, Lange F, Scheper T, Solle D, Bahnemann J. Establishment of a Perfusion Process with Antibody-Producing CHO Cells Using a 3D-Printed Microfluidic Spiral Separator with Web-Based Flow Control. Bioengineering. 2023 Jun;10(6):656. Epub 2023 Mai 28. doi: 10.3390/bioengineering10060656
Schellenberg, Jana ; Dehne, Michaela ; Lange, Ferdinand et al. / Establishment of a Perfusion Process with Antibody-Producing CHO Cells Using a 3D-Printed Microfluidic Spiral Separator with Web-Based Flow Control. in: Bioengineering. 2023 ; Jahrgang 10, Nr. 6.
Download
@article{69bdd63ecb614befb1de9f19fe3936a6,
title = "Establishment of a Perfusion Process with Antibody-Producing CHO Cells Using a 3D-Printed Microfluidic Spiral Separator with Web-Based Flow Control",
abstract = "Monoclonal antibodies are increasingly dominating the market for human therapeutic and diagnostic agents. For this reason, continuous methods—such as perfusion processes—are being explored and optimized in an ongoing effort to increase product yields. Unfortunately, many established cell retention devices—such as tangential flow filtration—rely on membranes that are prone to clogging, fouling, and undesirable product retention at high cell densities. To circumvent these problems, in this work, we have developed a 3D-printed microfluidic spiral separator for cell retention, which can readily be adapted and replaced according to process conditions (i.e., a plug-and-play system) due to the fast and flexible 3D printing technique. In addition, this system was also expanded to include automatic flushing, web-based control, and notification via a cellphone application. This set-up constitutes a proof of concept that was successful at inducing a stable process operation at a viable cell concentration of 10–17 × 106 cells/mL in a hybrid mode (with alternating cell retention and cell bleed phases) while significantly reducing both shear stress and channel blockage. In addition to increasing efficiency to nearly 100%, this microfluidic device also improved production conditions by successfully separating dead cells and cell debris and increasing cell viability within the bioreactor.",
keywords = "3D printing, cell retention, CHO, microfluidic spiral separator, monoclonal antibodies, perfusion, web-based flow monitoring",
author = "Jana Schellenberg and Michaela Dehne and Ferdinand Lange and Thomas Scheper and D{\"o}rte Solle and Janina Bahnemann",
note = "Funding Information: The authors would like to acknowledge and thank Sartorius Stedim Cellca GmbH, DE for providing the antibody-producing DG44 CHO cell line. Michaela Dehne is supported by the Add-on Fellowship of the Joachim Herz Foundation. Furthermore, a sincere thank you goes to Ole J. Wohlenberg and Anton Enders for their support in writing this article. Funding Information: Part of this research was funded by German Research Foundation (DFG), via the Emmy Noether Programme, grant number 346772917 (Janina Bahnemann).",
year = "2023",
month = jun,
doi = "10.3390/bioengineering10060656",
language = "English",
volume = "10",
number = "6",

}

Download

TY - JOUR

T1 - Establishment of a Perfusion Process with Antibody-Producing CHO Cells Using a 3D-Printed Microfluidic Spiral Separator with Web-Based Flow Control

AU - Schellenberg, Jana

AU - Dehne, Michaela

AU - Lange, Ferdinand

AU - Scheper, Thomas

AU - Solle, Dörte

AU - Bahnemann, Janina

N1 - Funding Information: The authors would like to acknowledge and thank Sartorius Stedim Cellca GmbH, DE for providing the antibody-producing DG44 CHO cell line. Michaela Dehne is supported by the Add-on Fellowship of the Joachim Herz Foundation. Furthermore, a sincere thank you goes to Ole J. Wohlenberg and Anton Enders for their support in writing this article. Funding Information: Part of this research was funded by German Research Foundation (DFG), via the Emmy Noether Programme, grant number 346772917 (Janina Bahnemann).

PY - 2023/6

Y1 - 2023/6

N2 - Monoclonal antibodies are increasingly dominating the market for human therapeutic and diagnostic agents. For this reason, continuous methods—such as perfusion processes—are being explored and optimized in an ongoing effort to increase product yields. Unfortunately, many established cell retention devices—such as tangential flow filtration—rely on membranes that are prone to clogging, fouling, and undesirable product retention at high cell densities. To circumvent these problems, in this work, we have developed a 3D-printed microfluidic spiral separator for cell retention, which can readily be adapted and replaced according to process conditions (i.e., a plug-and-play system) due to the fast and flexible 3D printing technique. In addition, this system was also expanded to include automatic flushing, web-based control, and notification via a cellphone application. This set-up constitutes a proof of concept that was successful at inducing a stable process operation at a viable cell concentration of 10–17 × 106 cells/mL in a hybrid mode (with alternating cell retention and cell bleed phases) while significantly reducing both shear stress and channel blockage. In addition to increasing efficiency to nearly 100%, this microfluidic device also improved production conditions by successfully separating dead cells and cell debris and increasing cell viability within the bioreactor.

AB - Monoclonal antibodies are increasingly dominating the market for human therapeutic and diagnostic agents. For this reason, continuous methods—such as perfusion processes—are being explored and optimized in an ongoing effort to increase product yields. Unfortunately, many established cell retention devices—such as tangential flow filtration—rely on membranes that are prone to clogging, fouling, and undesirable product retention at high cell densities. To circumvent these problems, in this work, we have developed a 3D-printed microfluidic spiral separator for cell retention, which can readily be adapted and replaced according to process conditions (i.e., a plug-and-play system) due to the fast and flexible 3D printing technique. In addition, this system was also expanded to include automatic flushing, web-based control, and notification via a cellphone application. This set-up constitutes a proof of concept that was successful at inducing a stable process operation at a viable cell concentration of 10–17 × 106 cells/mL in a hybrid mode (with alternating cell retention and cell bleed phases) while significantly reducing both shear stress and channel blockage. In addition to increasing efficiency to nearly 100%, this microfluidic device also improved production conditions by successfully separating dead cells and cell debris and increasing cell viability within the bioreactor.

KW - 3D printing

KW - cell retention

KW - CHO

KW - microfluidic spiral separator

KW - monoclonal antibodies

KW - perfusion

KW - web-based flow monitoring

UR - http://www.scopus.com/inward/record.url?scp=85163742335&partnerID=8YFLogxK

U2 - 10.3390/bioengineering10060656

DO - 10.3390/bioengineering10060656

M3 - Article

AN - SCOPUS:85163742335

VL - 10

JO - Bioengineering

JF - Bioengineering

IS - 6

M1 - 656

ER -

Von denselben Autoren