Comparison of colorimetric methods for the quantification of model proteins in aqueous two-phase systems

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)35-37
Seitenumfang3
FachzeitschriftAnalytical biochemistry
Jahrgang477
Frühes Online-Datum12 Feb. 2015
PublikationsstatusVeröffentlicht - 15 Mai 2015

Abstract

In the current study, the quantification of different model proteins in the presence of typical aqueous two-phase system components was investigated by using the Bradford and bicinchoninic acid (BCA) assays. Each phase-forming component above 1 and 5 wt% had considerable effects on the protein quantification in both assays, respectively, resulting in diminished protein recoveries/absorption values by increasing poly(ethylene glycol) (PEG)/salt concentration and PEG molecular weight. Therefore, a convenient dilution of both components (up to 1 and 5 wt%) before protein quantification is recommended in both assays, respectively, where the BCA assay is favored in comparison with the Bradford assay.

ASJC Scopus Sachgebiete

  • Biochemie, Genetik und Molekularbiologie (insg.)
  • Biophysik
  • Biochemie, Genetik und Molekularbiologie (insg.)
  • Biochemie
  • Biochemie, Genetik und Molekularbiologie (insg.)
  • Molekularbiologie
  • Biochemie, Genetik und Molekularbiologie (insg.)
  • Zellbiologie

Zitieren

Comparison of colorimetric methods for the quantification of model proteins in aqueous two-phase systems. / Glyk, Anna; Heinisch, Sandra L.; Scheper, Thomas et al.
in: Analytical biochemistry, Jahrgang 477, 15.05.2015, S. 35-37.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Glyk A, Heinisch SL, Scheper T, Beutel S. Comparison of colorimetric methods for the quantification of model proteins in aqueous two-phase systems. Analytical biochemistry. 2015 Mai 15;477:35-37. Epub 2015 Feb 12. doi: 10.15488/1324, 10.1016/j.ab.2015.02.007
Download
@article{bb192ebcbc2c45279ac7afedc8d61244,
title = "Comparison of colorimetric methods for the quantification of model proteins in aqueous two-phase systems",
abstract = "In the current study, the quantification of different model proteins in the presence of typical aqueous two-phase system components was investigated by using the Bradford and bicinchoninic acid (BCA) assays. Each phase-forming component above 1 and 5 wt% had considerable effects on the protein quantification in both assays, respectively, resulting in diminished protein recoveries/absorption values by increasing poly(ethylene glycol) (PEG)/salt concentration and PEG molecular weight. Therefore, a convenient dilution of both components (up to 1 and 5 wt%) before protein quantification is recommended in both assays, respectively, where the BCA assay is favored in comparison with the Bradford assay.",
keywords = "Aqueous two-phase system, BCA assay, Bradford assay, Colorimetric analysis, Protein quantification",
author = "Anna Glyk and Heinisch, {Sandra L.} and Thomas Scheper and Sascha Beutel",
year = "2015",
month = may,
day = "15",
doi = "10.15488/1324",
language = "English",
volume = "477",
pages = "35--37",
journal = "Analytical biochemistry",
issn = "0003-2697",
publisher = "Academic Press Inc.",

}

Download

TY - JOUR

T1 - Comparison of colorimetric methods for the quantification of model proteins in aqueous two-phase systems

AU - Glyk, Anna

AU - Heinisch, Sandra L.

AU - Scheper, Thomas

AU - Beutel, Sascha

PY - 2015/5/15

Y1 - 2015/5/15

N2 - In the current study, the quantification of different model proteins in the presence of typical aqueous two-phase system components was investigated by using the Bradford and bicinchoninic acid (BCA) assays. Each phase-forming component above 1 and 5 wt% had considerable effects on the protein quantification in both assays, respectively, resulting in diminished protein recoveries/absorption values by increasing poly(ethylene glycol) (PEG)/salt concentration and PEG molecular weight. Therefore, a convenient dilution of both components (up to 1 and 5 wt%) before protein quantification is recommended in both assays, respectively, where the BCA assay is favored in comparison with the Bradford assay.

AB - In the current study, the quantification of different model proteins in the presence of typical aqueous two-phase system components was investigated by using the Bradford and bicinchoninic acid (BCA) assays. Each phase-forming component above 1 and 5 wt% had considerable effects on the protein quantification in both assays, respectively, resulting in diminished protein recoveries/absorption values by increasing poly(ethylene glycol) (PEG)/salt concentration and PEG molecular weight. Therefore, a convenient dilution of both components (up to 1 and 5 wt%) before protein quantification is recommended in both assays, respectively, where the BCA assay is favored in comparison with the Bradford assay.

KW - Aqueous two-phase system

KW - BCA assay

KW - Bradford assay

KW - Colorimetric analysis

KW - Protein quantification

UR - http://www.scopus.com/inward/record.url?scp=84963937436&partnerID=8YFLogxK

U2 - 10.15488/1324

DO - 10.15488/1324

M3 - Article

C2 - 25684109

AN - SCOPUS:84963937436

VL - 477

SP - 35

EP - 37

JO - Analytical biochemistry

JF - Analytical biochemistry

SN - 0003-2697