Details
Original language | English |
---|---|
Pages (from-to) | 204-218 |
Number of pages | 15 |
Journal | Acoustics |
Volume | 6 |
Issue number | 1 |
Publication status | Published - 20 Feb 2024 |
Abstract
Regular inspections of important civil infrastructures are mandatory to ensure structural safety and reliability. Until today, these inspections are primarily conducted manually, which has several deficiencies. In context of prestressed concrete structures, steel tendons can be susceptible to stress corrosion cracking, which may result in breakage of individual wires that is visually not observable. Recent research therefore suggests Acoustic Emission Monitoring for wire break detection in prestressed concrete structures. However, in noisy environments, such as wind turbines, conventional acoustic emission detection based on user-defined amplitude thresholds may not be suitable. Thus, we propose the use of matched filters for acoustic emission detection in noisy environments and apply the proposed method to the task of wire break detection in post-tensioned wind turbine towers. Based on manually conducted wire breaks and rebound hammer tests on a large-scale test frame, we employ a brute-force search for the most suitable query signal of a wire break event and a rebound hammer impact, respectively. Then, we evaluate the signal detection performance on more than 500 other wire break signals and approximately one week of continuous acoustic emission recordings in an operating wind turbine. For a signal-to-noise ratio of 0 dB, the matched filter approach shows an improvement in AUC by up to 0.78 for both, the wire break and the rebound hammer query signal, compared to state-of-the-art amplitude-based detection. Even for the unscaled wire break measurements originally recorded at the 12 m large laboratory test frame, the improvement in AUC still lies between 0.01 and 0.25 depending on the wind turbine noise recordings considered for evaluation. Matched filters may therefore be a promising alternative to amplitude-based detection algorithms and deserve particular consideration with regard to Acoustic Emission Monitoring, especially in noisy environments or when sparse senor networks are required.
Keywords
- acoustic emission, bridge monitoring, damage detection, matched filter, non-destructive testing, pattern matching, structural health monitoring
ASJC Scopus subject areas
- Physics and Astronomy(all)
- Acoustics and Ultrasonics
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
In: Acoustics, Vol. 6, No. 1, 20.02.2024, p. 204-218.
Research output: Contribution to journal › Article › Research › peer review
}
TY - JOUR
T1 - Matched Filter for Acoustic Emission Monitoring in Noisy Environments
T2 - Application to Wire Break Detection
AU - Lange, Alexander
AU - Xu, Ronghua
AU - Kaeding, Max
AU - Ostermann, Joern
AU - Marx, Steffen
N1 - Funding Information: This research was funded by German Federal Ministry for Economic Affairs and Climate Action under grant number 03EE2025B. The APC was funded.
PY - 2024/2/20
Y1 - 2024/2/20
N2 - Regular inspections of important civil infrastructures are mandatory to ensure structural safety and reliability. Until today, these inspections are primarily conducted manually, which has several deficiencies. In context of prestressed concrete structures, steel tendons can be susceptible to stress corrosion cracking, which may result in breakage of individual wires that is visually not observable. Recent research therefore suggests Acoustic Emission Monitoring for wire break detection in prestressed concrete structures. However, in noisy environments, such as wind turbines, conventional acoustic emission detection based on user-defined amplitude thresholds may not be suitable. Thus, we propose the use of matched filters for acoustic emission detection in noisy environments and apply the proposed method to the task of wire break detection in post-tensioned wind turbine towers. Based on manually conducted wire breaks and rebound hammer tests on a large-scale test frame, we employ a brute-force search for the most suitable query signal of a wire break event and a rebound hammer impact, respectively. Then, we evaluate the signal detection performance on more than 500 other wire break signals and approximately one week of continuous acoustic emission recordings in an operating wind turbine. For a signal-to-noise ratio of 0 dB, the matched filter approach shows an improvement in AUC by up to 0.78 for both, the wire break and the rebound hammer query signal, compared to state-of-the-art amplitude-based detection. Even for the unscaled wire break measurements originally recorded at the 12 m large laboratory test frame, the improvement in AUC still lies between 0.01 and 0.25 depending on the wind turbine noise recordings considered for evaluation. Matched filters may therefore be a promising alternative to amplitude-based detection algorithms and deserve particular consideration with regard to Acoustic Emission Monitoring, especially in noisy environments or when sparse senor networks are required.
AB - Regular inspections of important civil infrastructures are mandatory to ensure structural safety and reliability. Until today, these inspections are primarily conducted manually, which has several deficiencies. In context of prestressed concrete structures, steel tendons can be susceptible to stress corrosion cracking, which may result in breakage of individual wires that is visually not observable. Recent research therefore suggests Acoustic Emission Monitoring for wire break detection in prestressed concrete structures. However, in noisy environments, such as wind turbines, conventional acoustic emission detection based on user-defined amplitude thresholds may not be suitable. Thus, we propose the use of matched filters for acoustic emission detection in noisy environments and apply the proposed method to the task of wire break detection in post-tensioned wind turbine towers. Based on manually conducted wire breaks and rebound hammer tests on a large-scale test frame, we employ a brute-force search for the most suitable query signal of a wire break event and a rebound hammer impact, respectively. Then, we evaluate the signal detection performance on more than 500 other wire break signals and approximately one week of continuous acoustic emission recordings in an operating wind turbine. For a signal-to-noise ratio of 0 dB, the matched filter approach shows an improvement in AUC by up to 0.78 for both, the wire break and the rebound hammer query signal, compared to state-of-the-art amplitude-based detection. Even for the unscaled wire break measurements originally recorded at the 12 m large laboratory test frame, the improvement in AUC still lies between 0.01 and 0.25 depending on the wind turbine noise recordings considered for evaluation. Matched filters may therefore be a promising alternative to amplitude-based detection algorithms and deserve particular consideration with regard to Acoustic Emission Monitoring, especially in noisy environments or when sparse senor networks are required.
KW - acoustic emission
KW - bridge monitoring
KW - damage detection
KW - matched filter
KW - non-destructive testing
KW - pattern matching
KW - structural health monitoring
UR - http://www.scopus.com/inward/record.url?scp=85188816966&partnerID=8YFLogxK
U2 - 10.3390/acoustics6010011
DO - 10.3390/acoustics6010011
M3 - Article
AN - SCOPUS:85188816966
VL - 6
SP - 204
EP - 218
JO - Acoustics
JF - Acoustics
IS - 1
ER -