Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy

Publikation: Beitrag in FachzeitschriftKonferenzaufsatz in FachzeitschriftForschungPeer-Review

Autorschaft

  • N. Poljakov
  • J. Schaper
  • J. A. Coenders
  • J. M. Cornejo
  • S. Ulmer
  • C. Ospelkaus

Externe Organisationen

  • Ulmer Fundamental Symmetries Laboratory
  • Universitätsklinikum Düsseldorf
  • Physikalisch-Technische Bundesanstalt (PTB)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer102
FachzeitschriftProceedings of Science
Jahrgang480
Frühes Online-Datum3 März 2025
PublikationsstatusVeröffentlicht - 7 Juli 2025
Veranstaltung2024 Exotic Atoms and Related Topics Conference and the Low Energy Antiproton Conference, EXA-LEAP 2024 - Austrian Academy of Sciences, Vienna, Vienna, Österreich
Dauer: 26 Aug. 202430 Aug. 2024

Abstract

We present the latest upgrades of our cryogenic multi-Penning-trap stack to implement quantum logic cooling and detection techniques for g-factor measurements of (anti-)protons within the BASE collaboration. This updated trap system has been designed to cool single protons to their motional ground state, a key feature for the implementation of quantum logic spectroscopy on (anti-)protons in Penning traps. For this purpose, a double-well potential will be generated in our trap system in order to implement free Coulomb coupling between a single proton and a 9Be+ ion, allowing sympathetic cooling of single protons, as well as a spin-motion SWAP gate for spin state detection. The application of these techniques to antiprotons later will allow to increase the sampling rates of current (anti-)proton g-factor measurements, and thus contribute to the search for CPT violating coefficients acting on baryons in the Standard Model extension.

ASJC Scopus Sachgebiete

Zitieren

Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy. / Poljakov, N.; Schaper, J.; Coenders, J. A. et al.
in: Proceedings of Science, Jahrgang 480, 102, 07.07.2025.

Publikation: Beitrag in FachzeitschriftKonferenzaufsatz in FachzeitschriftForschungPeer-Review

Poljakov, N, Schaper, J, Coenders, JA, Cornejo, JM, Ulmer, S & Ospelkaus, C 2025, 'Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy', Proceedings of Science, Jg. 480, 102. https://doi.org/10.22323/1.480.0102
Poljakov, N., Schaper, J., Coenders, J. A., Cornejo, J. M., Ulmer, S., & Ospelkaus, C. (2025). Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy. Proceedings of Science, 480, Artikel 102. https://doi.org/10.22323/1.480.0102
Poljakov N, Schaper J, Coenders JA, Cornejo JM, Ulmer S, Ospelkaus C. Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy. Proceedings of Science. 2025 Jul 7;480:102. Epub 2025 Mär 3. doi: 10.22323/1.480.0102
Poljakov, N. ; Schaper, J. ; Coenders, J. A. et al. / Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy. in: Proceedings of Science. 2025 ; Jahrgang 480.
Download
@article{f9d182d7889e45718ef81d48a126936d,
title = "Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy",
abstract = "We present the latest upgrades of our cryogenic multi-Penning-trap stack to implement quantum logic cooling and detection techniques for g-factor measurements of (anti-)protons within the BASE collaboration. This updated trap system has been designed to cool single protons to their motional ground state, a key feature for the implementation of quantum logic spectroscopy on (anti-)protons in Penning traps. For this purpose, a double-well potential will be generated in our trap system in order to implement free Coulomb coupling between a single proton and a 9Be+ ion, allowing sympathetic cooling of single protons, as well as a spin-motion SWAP gate for spin state detection. The application of these techniques to antiprotons later will allow to increase the sampling rates of current (anti-)proton g-factor measurements, and thus contribute to the search for CPT violating coefficients acting on baryons in the Standard Model extension.",
author = "N. Poljakov and J. Schaper and Coenders, {J. A.} and Cornejo, {J. M.} and S. Ulmer and C. Ospelkaus",
note = "Publisher Copyright: {\textcopyright} Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).; 2024 Exotic Atoms and Related Topics Conference and the Low Energy Antiproton Conference, EXA-LEAP 2024, EXA-LEAP 2024 ; Conference date: 26-08-2024 Through 30-08-2024",
year = "2025",
month = jul,
day = "7",
doi = "10.22323/1.480.0102",
language = "English",
volume = "480",

}

Download

TY - JOUR

T1 - Towards g-factor measurements of (anti-)protons using techniques based on quantum logic spectroscopy

AU - Poljakov, N.

AU - Schaper, J.

AU - Coenders, J. A.

AU - Cornejo, J. M.

AU - Ulmer, S.

AU - Ospelkaus, C.

N1 - Publisher Copyright: © Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).

PY - 2025/7/7

Y1 - 2025/7/7

N2 - We present the latest upgrades of our cryogenic multi-Penning-trap stack to implement quantum logic cooling and detection techniques for g-factor measurements of (anti-)protons within the BASE collaboration. This updated trap system has been designed to cool single protons to their motional ground state, a key feature for the implementation of quantum logic spectroscopy on (anti-)protons in Penning traps. For this purpose, a double-well potential will be generated in our trap system in order to implement free Coulomb coupling between a single proton and a 9Be+ ion, allowing sympathetic cooling of single protons, as well as a spin-motion SWAP gate for spin state detection. The application of these techniques to antiprotons later will allow to increase the sampling rates of current (anti-)proton g-factor measurements, and thus contribute to the search for CPT violating coefficients acting on baryons in the Standard Model extension.

AB - We present the latest upgrades of our cryogenic multi-Penning-trap stack to implement quantum logic cooling and detection techniques for g-factor measurements of (anti-)protons within the BASE collaboration. This updated trap system has been designed to cool single protons to their motional ground state, a key feature for the implementation of quantum logic spectroscopy on (anti-)protons in Penning traps. For this purpose, a double-well potential will be generated in our trap system in order to implement free Coulomb coupling between a single proton and a 9Be+ ion, allowing sympathetic cooling of single protons, as well as a spin-motion SWAP gate for spin state detection. The application of these techniques to antiprotons later will allow to increase the sampling rates of current (anti-)proton g-factor measurements, and thus contribute to the search for CPT violating coefficients acting on baryons in the Standard Model extension.

UR - http://www.scopus.com/inward/record.url?scp=105010599921&partnerID=8YFLogxK

U2 - 10.22323/1.480.0102

DO - 10.22323/1.480.0102

M3 - Conference article

AN - SCOPUS:105010599921

VL - 480

JO - Proceedings of Science

JF - Proceedings of Science

M1 - 102

T2 - 2024 Exotic Atoms and Related Topics Conference and the Low Energy Antiproton Conference, EXA-LEAP 2024

Y2 - 26 August 2024 through 30 August 2024

ER -

Von denselben Autoren