Simulation processes and an experimental test are performed to investigate the practicability of using the time domain reflectometry (TDR) for the detection of defects in pipelines. Similar to the employment of TDR in checking electrical wiring it may serve to evaluate the position and the degree of a defect. Various simulation models are used to learn about the correlation between the quality of the defect and the reflected signals. A simplified laboratory model is set up for conducting trials with a TDR measurement device. Especially for online monitoring of horizontal pipeline drillings the method could provide an improvement over conventional approaches.
Schlagwörter
- Fault locating, Pipeline monitoring, Pulling process, TDR, Time domain reflectometry
ASJC Scopus Sachgebiete
- Betriebswirtschaft, Management und Rechnungswesen (insg.)
- Management-Informationssysteme
- Ingenieurwesen (insg.)
- Steuerungs- und Systemtechnik
- Entscheidungswissenschaften (insg.)
- Managementlehre und Operations Resarch
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Logistics Journal, Jahrgang 2016, 27.05.2016.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Schadensdetektion an Rohrleitungen mittels Zeitbereichsreflektometrie
AU - von der Ahe, Christoph
AU - Overmeyer, Ludger
PY - 2016/5/27
Y1 - 2016/5/27
N2 - Simulation processes and an experimental test are performed to investigate the practicability of using the time domain reflectometry (TDR) for the detection of defects in pipelines. Similar to the employment of TDR in checking electrical wiring it may serve to evaluate the position and the degree of a defect. Various simulation models are used to learn about the correlation between the quality of the defect and the reflected signals. A simplified laboratory model is set up for conducting trials with a TDR measurement device. Especially for online monitoring of horizontal pipeline drillings the method could provide an improvement over conventional approaches.
AB - Simulation processes and an experimental test are performed to investigate the practicability of using the time domain reflectometry (TDR) for the detection of defects in pipelines. Similar to the employment of TDR in checking electrical wiring it may serve to evaluate the position and the degree of a defect. Various simulation models are used to learn about the correlation between the quality of the defect and the reflected signals. A simplified laboratory model is set up for conducting trials with a TDR measurement device. Especially for online monitoring of horizontal pipeline drillings the method could provide an improvement over conventional approaches.
KW - Fault locating
KW - Pipeline monitoring
KW - Pulling process
KW - TDR
KW - Time domain reflectometry
UR - http://www.scopus.com/inward/record.url?scp=84975246721&partnerID=8YFLogxK
U2 - 10.2195/lj_Proc_vonderahe_de_201605_01
DO - 10.2195/lj_Proc_vonderahe_de_201605_01
M3 - Artikel
AN - SCOPUS:84975246721
VL - 2016
JO - Logistics Journal
JF - Logistics Journal
SN - 1860-7977
ER -