On-line immunoanalysis for bioprocess control

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

  • C. Middendorf
  • B. Schulze
  • R. Freitag
  • Th Scheper
  • M. Howaldt
  • H. Hoffmann

Externe Organisationen

  • Westfälische Wilhelms-Universität Münster (WWU)
  • Boehringer Ingelheim
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)395-403
Seitenumfang9
FachzeitschriftJournal of biotechnology
Jahrgang31
Ausgabenummer3
PublikationsstatusVeröffentlicht - Dez. 1993
Extern publiziertJa

Abstract

Immunoanalytical techniques such as ELISA are often used for the detection of proteins produced in cultivation processes. Owing to the difficulty of automating of the time-consuming traditional ELISA, there is an intense demand for a suitable on-line monitoring method. Combining well-known immunoassays with the FIA technique, we present the heterogeneous and the turbidimetric immuno-FIA methods. The following proteins were investigated with these FIA methods: thermostable pullulanase, IgG, antithrombin III, and recombinant tissue-type plasminogen activator. In the cases of pullulanase and monoclonal mouse IgG, the turbidimetric immuno-FIA was used for on-line analysis of the cultivation process. Results are presented here to demonstrate the effectiveness and application of these immunoanalyses.

ASJC Scopus Sachgebiete

Zitieren

On-line immunoanalysis for bioprocess control. / Middendorf, C.; Schulze, B.; Freitag, R. et al.
in: Journal of biotechnology, Jahrgang 31, Nr. 3, 12.1993, S. 395-403.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Middendorf, C, Schulze, B, Freitag, R, Scheper, T, Howaldt, M & Hoffmann, H 1993, 'On-line immunoanalysis for bioprocess control', Journal of biotechnology, Jg. 31, Nr. 3, S. 395-403. https://doi.org/10.1016/0168-1656(93)90083-Y
Middendorf, C., Schulze, B., Freitag, R., Scheper, T., Howaldt, M., & Hoffmann, H. (1993). On-line immunoanalysis for bioprocess control. Journal of biotechnology, 31(3), 395-403. https://doi.org/10.1016/0168-1656(93)90083-Y
Middendorf C, Schulze B, Freitag R, Scheper T, Howaldt M, Hoffmann H. On-line immunoanalysis for bioprocess control. Journal of biotechnology. 1993 Dez;31(3):395-403. doi: 10.1016/0168-1656(93)90083-Y
Middendorf, C. ; Schulze, B. ; Freitag, R. et al. / On-line immunoanalysis for bioprocess control. in: Journal of biotechnology. 1993 ; Jahrgang 31, Nr. 3. S. 395-403.
Download
@article{c63f025ec0794c36b8f4b61fc0e4d099,
title = "On-line immunoanalysis for bioprocess control",
abstract = "Immunoanalytical techniques such as ELISA are often used for the detection of proteins produced in cultivation processes. Owing to the difficulty of automating of the time-consuming traditional ELISA, there is an intense demand for a suitable on-line monitoring method. Combining well-known immunoassays with the FIA technique, we present the heterogeneous and the turbidimetric immuno-FIA methods. The following proteins were investigated with these FIA methods: thermostable pullulanase, IgG, antithrombin III, and recombinant tissue-type plasminogen activator. In the cases of pullulanase and monoclonal mouse IgG, the turbidimetric immuno-FIA was used for on-line analysis of the cultivation process. Results are presented here to demonstrate the effectiveness and application of these immunoanalyses.",
keywords = "FIA, Flow injection analysis, On-line monitoring, Process control, Tissue-type plasminogen activator, Turbidimetric immunoassay",
author = "C. Middendorf and B. Schulze and R. Freitag and Th Scheper and M. Howaldt and H. Hoffmann",
year = "1993",
month = dec,
doi = "10.1016/0168-1656(93)90083-Y",
language = "English",
volume = "31",
pages = "395--403",
journal = "Journal of biotechnology",
issn = "0168-1656",
publisher = "Elsevier",
number = "3",

}

Download

TY - JOUR

T1 - On-line immunoanalysis for bioprocess control

AU - Middendorf, C.

AU - Schulze, B.

AU - Freitag, R.

AU - Scheper, Th

AU - Howaldt, M.

AU - Hoffmann, H.

PY - 1993/12

Y1 - 1993/12

N2 - Immunoanalytical techniques such as ELISA are often used for the detection of proteins produced in cultivation processes. Owing to the difficulty of automating of the time-consuming traditional ELISA, there is an intense demand for a suitable on-line monitoring method. Combining well-known immunoassays with the FIA technique, we present the heterogeneous and the turbidimetric immuno-FIA methods. The following proteins were investigated with these FIA methods: thermostable pullulanase, IgG, antithrombin III, and recombinant tissue-type plasminogen activator. In the cases of pullulanase and monoclonal mouse IgG, the turbidimetric immuno-FIA was used for on-line analysis of the cultivation process. Results are presented here to demonstrate the effectiveness and application of these immunoanalyses.

AB - Immunoanalytical techniques such as ELISA are often used for the detection of proteins produced in cultivation processes. Owing to the difficulty of automating of the time-consuming traditional ELISA, there is an intense demand for a suitable on-line monitoring method. Combining well-known immunoassays with the FIA technique, we present the heterogeneous and the turbidimetric immuno-FIA methods. The following proteins were investigated with these FIA methods: thermostable pullulanase, IgG, antithrombin III, and recombinant tissue-type plasminogen activator. In the cases of pullulanase and monoclonal mouse IgG, the turbidimetric immuno-FIA was used for on-line analysis of the cultivation process. Results are presented here to demonstrate the effectiveness and application of these immunoanalyses.

KW - FIA

KW - Flow injection analysis

KW - On-line monitoring

KW - Process control

KW - Tissue-type plasminogen activator

KW - Turbidimetric immunoassay

UR - http://www.scopus.com/inward/record.url?scp=0027743394&partnerID=8YFLogxK

U2 - 10.1016/0168-1656(93)90083-Y

DO - 10.1016/0168-1656(93)90083-Y

M3 - Article

C2 - 7764446

AN - SCOPUS:0027743394

VL - 31

SP - 395

EP - 403

JO - Journal of biotechnology

JF - Journal of biotechnology

SN - 0168-1656

IS - 3

ER -

Von denselben Autoren