Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 1891-1897 |
Seitenumfang | 7 |
Fachzeitschrift | Lasers in medical science |
Jahrgang | 37 |
Ausgabenummer | 3 |
Frühes Online-Datum | 29 Okt. 2021 |
Publikationsstatus | Veröffentlicht - Apr. 2022 |
Abstract
Background: In this study, the tear resistance of porcine lens capsules after continuous curvilinear capsulorhexis (CCC) and femtosecond (fs)-laser-assisted capsulotomy for cataract surgery (FLC) with different laser parameters is measured with a custom-made testing setup. Methods: Forty-five fresh porcine lenses were randomly chosen for CCC (n = 15) or FLC 1 (n = 15) and FLC 2 (n = 15). The FLC 1-group was treated with smaller spot distances than the FLC 2-group. The force necessary to break the opening of the anterior capsule and the maximum displacement were measured. Results: The mean tear resistance of the CCC-group (150 ± 70 mN) was higher than that of the FLC 1-group (60 ± 20 mN) and the FLC 2-group (30 ± 20 mN). Conclusion: It could be shown that CCC leads to a significantly higher tear resistance of the opening than FLC in porcine lenses. The femtosecond laser group demonstrated that smaller spot distances lead to a higher tear resistance.
ASJC Scopus Sachgebiete
- Medizin (insg.)
- Chirurgie
- Medizin (insg.)
- Dermatologie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Lasers in medical science, Jahrgang 37, Nr. 3, 04.2022, S. 1891-1897.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Measurement of tear resistance after manual capsulorhexis and femtosecond laser–assisted capsulotomy of crystalline lenses
AU - Patzlaff-Günther, Mandy
AU - Fromm, Michael
AU - Kern, Thomas
AU - Bartram, Martin
AU - Schwäblein, Anna
AU - Heinemann, Dag
AU - Johannsmeier, Sonja
AU - Framme, Carsten
AU - Ripken, Tammo
N1 - Funding Information: We thank the Deutsche Gesellschaft für Gewebetransplantation gGmbH (DGFG) for the support with human donor lenses.
PY - 2022/4
Y1 - 2022/4
N2 - Background: In this study, the tear resistance of porcine lens capsules after continuous curvilinear capsulorhexis (CCC) and femtosecond (fs)-laser-assisted capsulotomy for cataract surgery (FLC) with different laser parameters is measured with a custom-made testing setup. Methods: Forty-five fresh porcine lenses were randomly chosen for CCC (n = 15) or FLC 1 (n = 15) and FLC 2 (n = 15). The FLC 1-group was treated with smaller spot distances than the FLC 2-group. The force necessary to break the opening of the anterior capsule and the maximum displacement were measured. Results: The mean tear resistance of the CCC-group (150 ± 70 mN) was higher than that of the FLC 1-group (60 ± 20 mN) and the FLC 2-group (30 ± 20 mN). Conclusion: It could be shown that CCC leads to a significantly higher tear resistance of the opening than FLC in porcine lenses. The femtosecond laser group demonstrated that smaller spot distances lead to a higher tear resistance.
AB - Background: In this study, the tear resistance of porcine lens capsules after continuous curvilinear capsulorhexis (CCC) and femtosecond (fs)-laser-assisted capsulotomy for cataract surgery (FLC) with different laser parameters is measured with a custom-made testing setup. Methods: Forty-five fresh porcine lenses were randomly chosen for CCC (n = 15) or FLC 1 (n = 15) and FLC 2 (n = 15). The FLC 1-group was treated with smaller spot distances than the FLC 2-group. The force necessary to break the opening of the anterior capsule and the maximum displacement were measured. Results: The mean tear resistance of the CCC-group (150 ± 70 mN) was higher than that of the FLC 1-group (60 ± 20 mN) and the FLC 2-group (30 ± 20 mN). Conclusion: It could be shown that CCC leads to a significantly higher tear resistance of the opening than FLC in porcine lenses. The femtosecond laser group demonstrated that smaller spot distances lead to a higher tear resistance.
KW - Cataract surgery
KW - Continuous curvilinear capsulorhexis
KW - Femtosecond (fs)-laser-assisted capsulotomy
KW - Lens refilling
KW - Phacoemulsification
KW - Tear resistance
UR - http://www.scopus.com/inward/record.url?scp=85118215750&partnerID=8YFLogxK
U2 - 10.1007/s10103-021-03448-1
DO - 10.1007/s10103-021-03448-1
M3 - Article
C2 - 34713366
AN - SCOPUS:85118215750
VL - 37
SP - 1891
EP - 1897
JO - Lasers in medical science
JF - Lasers in medical science
SN - 0268-8921
IS - 3
ER -