Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 301-305 |
Seitenumfang | 5 |
Fachzeitschrift | Analytica chimica acta |
Jahrgang | 309 |
Ausgabenummer | 1-3 |
Publikationsstatus | Veröffentlicht - 20 Juni 1995 |
Extern publiziert | Ja |
Abstract
A flow-injection analysis (FIA) system with an integrated immunobased elution assay was developed for the on-line determination of biotechnological products. This paper describes its application for tissue-type plasminogen activator (rt-PA) and recombinant antithrombin III (r-AT III). The short response time of the immunochemical system allows its use for measurement and control of biotechnological production processes. Immobilized polyclonal antibodies were found to bind rt-PA in the cartridge better than monoclonal antibodies. Sepharose-4B was found to be the best support for the antibodies. The cartridge with immobilized antibodies can be prepared easily, has a high reliability and is stable for more than two weeks. The total time necessary for one assay cycle is in the range of 6-8 min, depending on the conditions. The whole procedure is controlled by a personal computer. The FIA system can be used for automatic analysis as a stand-alone version with a frequency of 7 samples per hour. The standard operation range is from 500 μg/ml down to 2 μg/ml. A comparison with the conventional microtiter ELISA assay shows that this assay can be applied for an accurate determination of undiluted cultivation samples.
ASJC Scopus Sachgebiete
- Chemie (insg.)
- Analytische Chemie
- Biochemie, Genetik und Molekularbiologie (insg.)
- Biochemie
- Umweltwissenschaften (insg.)
- Umweltchemie
- Chemie (insg.)
- Spektroskopie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Analytica chimica acta, Jahrgang 309, Nr. 1-3, 20.06.1995, S. 301-305.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Immunobased elution assay for process control
AU - Beyer, Kerstin
AU - Reinecke, Martin
AU - Noe, Wolfgang
AU - Scheper, Thomas
PY - 1995/6/20
Y1 - 1995/6/20
N2 - A flow-injection analysis (FIA) system with an integrated immunobased elution assay was developed for the on-line determination of biotechnological products. This paper describes its application for tissue-type plasminogen activator (rt-PA) and recombinant antithrombin III (r-AT III). The short response time of the immunochemical system allows its use for measurement and control of biotechnological production processes. Immobilized polyclonal antibodies were found to bind rt-PA in the cartridge better than monoclonal antibodies. Sepharose-4B was found to be the best support for the antibodies. The cartridge with immobilized antibodies can be prepared easily, has a high reliability and is stable for more than two weeks. The total time necessary for one assay cycle is in the range of 6-8 min, depending on the conditions. The whole procedure is controlled by a personal computer. The FIA system can be used for automatic analysis as a stand-alone version with a frequency of 7 samples per hour. The standard operation range is from 500 μg/ml down to 2 μg/ml. A comparison with the conventional microtiter ELISA assay shows that this assay can be applied for an accurate determination of undiluted cultivation samples.
AB - A flow-injection analysis (FIA) system with an integrated immunobased elution assay was developed for the on-line determination of biotechnological products. This paper describes its application for tissue-type plasminogen activator (rt-PA) and recombinant antithrombin III (r-AT III). The short response time of the immunochemical system allows its use for measurement and control of biotechnological production processes. Immobilized polyclonal antibodies were found to bind rt-PA in the cartridge better than monoclonal antibodies. Sepharose-4B was found to be the best support for the antibodies. The cartridge with immobilized antibodies can be prepared easily, has a high reliability and is stable for more than two weeks. The total time necessary for one assay cycle is in the range of 6-8 min, depending on the conditions. The whole procedure is controlled by a personal computer. The FIA system can be used for automatic analysis as a stand-alone version with a frequency of 7 samples per hour. The standard operation range is from 500 μg/ml down to 2 μg/ml. A comparison with the conventional microtiter ELISA assay shows that this assay can be applied for an accurate determination of undiluted cultivation samples.
KW - Flow injection
KW - Immunoassay
KW - Process analysis
UR - http://www.scopus.com/inward/record.url?scp=0029008499&partnerID=8YFLogxK
U2 - 10.1016/0003-2670(95)00092-E
DO - 10.1016/0003-2670(95)00092-E
M3 - Article
AN - SCOPUS:0029008499
VL - 309
SP - 301
EP - 305
JO - Analytica chimica acta
JF - Analytica chimica acta
SN - 0003-2670
IS - 1-3
ER -