Deconvolution-based image enhancement for optical coherence tomography

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

  • Damian Mendroch
  • Niklas Bauer
  • David Harings
  • Alexander Heisterkamp

Organisationseinheiten

Externe Organisationen

  • Technische Hochschule Köln
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksBiomedical Spectroscopy, Microscopy, and Imaging III
Herausgeber/-innenJurgen Popp, Csilla Gergely
Herausgeber (Verlag)SPIE
ISBN (elektronisch)9781510673281
PublikationsstatusVeröffentlicht - 2024
VeranstaltungSPIE Photonics Europe 2024: Advances in Ultrafast Condensed Phase Physics IV - Strasbourg, Frankreich
Dauer: 7 Apr. 202411 Apr. 2024

Publikationsreihe

NameProceedings of SPIE - The International Society for Optical Engineering
Band13006
ISSN (Print)0277-786X
ISSN (elektronisch)1996-756X

Abstract

This work focuses on enhancing the quality of A- and B-scans of a novel linear optical coherence tomography system (LOCT), addressing the image degradation caused by noise and the blurring characteristics of the system’s three-dimensional point spread function. The enhancement procedure includes an initial spatial and frequency-based pre-filtering that is applied to the measured interference pattern. Subsequently, a more robust envelope detection technique based on the Hilbert transform is employed. Lastly, image structures are reconstructed using a deconvolution algorithm based on maximum likelihood estimation, tailored to meet our unique requirements by adapting it to Rician distributed intensity values and employing a sparseness regularization term. For the deconvolution, both the lateral and axial blur of the system are considered. Emphasis is placed on the optimization of signal detection in high-noise regions, while simultaneously preventing image boundary artifacts. The efficacy of this approach is demonstrated across multiple types of measurement objects, including both artificial and biological samples. All results show a significant reduction in noise as well as enhanced resolution. Structure distinguishability is also increased, which plays a crucial role in tomography applications. In summary, the proposed enhancement method substantially improves image quality. This is achieved by still using the same initial measurement data, but incorporating prior knowledge and maximizing the amount of extracted information. Although initially designed for LOCT systems, the processing steps have potential for broader application in other types of optical coherence tomography and imaging systems.

ASJC Scopus Sachgebiete

Zitieren

Deconvolution-based image enhancement for optical coherence tomography. / Mendroch, Damian; Bauer, Niklas; Harings, David et al.
Biomedical Spectroscopy, Microscopy, and Imaging III. Hrsg. / Jurgen Popp; Csilla Gergely. SPIE, 2024. 130061A (Proceedings of SPIE - The International Society for Optical Engineering; Band 13006).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Mendroch, D, Bauer, N, Harings, D & Heisterkamp, A 2024, Deconvolution-based image enhancement for optical coherence tomography. in J Popp & C Gergely (Hrsg.), Biomedical Spectroscopy, Microscopy, and Imaging III., 130061A, Proceedings of SPIE - The International Society for Optical Engineering, Bd. 13006, SPIE, SPIE Photonics Europe 2024, Strasbourg, Frankreich, 7 Apr. 2024. https://doi.org/10.1117/12.3016987
Mendroch, D., Bauer, N., Harings, D., & Heisterkamp, A. (2024). Deconvolution-based image enhancement for optical coherence tomography. In J. Popp, & C. Gergely (Hrsg.), Biomedical Spectroscopy, Microscopy, and Imaging III Artikel 130061A (Proceedings of SPIE - The International Society for Optical Engineering; Band 13006). SPIE. https://doi.org/10.1117/12.3016987
Mendroch D, Bauer N, Harings D, Heisterkamp A. Deconvolution-based image enhancement for optical coherence tomography. in Popp J, Gergely C, Hrsg., Biomedical Spectroscopy, Microscopy, and Imaging III. SPIE. 2024. 130061A. (Proceedings of SPIE - The International Society for Optical Engineering). Epub 2024 Jun 20. doi: 10.1117/12.3016987
Mendroch, Damian ; Bauer, Niklas ; Harings, David et al. / Deconvolution-based image enhancement for optical coherence tomography. Biomedical Spectroscopy, Microscopy, and Imaging III. Hrsg. / Jurgen Popp ; Csilla Gergely. SPIE, 2024. (Proceedings of SPIE - The International Society for Optical Engineering).
Download
@inproceedings{daa36e21ff75495c87ecbebe113a3db8,
title = "Deconvolution-based image enhancement for optical coherence tomography",
abstract = "This work focuses on enhancing the quality of A- and B-scans of a novel linear optical coherence tomography system (LOCT), addressing the image degradation caused by noise and the blurring characteristics of the system{\textquoteright}s three-dimensional point spread function. The enhancement procedure includes an initial spatial and frequency-based pre-filtering that is applied to the measured interference pattern. Subsequently, a more robust envelope detection technique based on the Hilbert transform is employed. Lastly, image structures are reconstructed using a deconvolution algorithm based on maximum likelihood estimation, tailored to meet our unique requirements by adapting it to Rician distributed intensity values and employing a sparseness regularization term. For the deconvolution, both the lateral and axial blur of the system are considered. Emphasis is placed on the optimization of signal detection in high-noise regions, while simultaneously preventing image boundary artifacts. The efficacy of this approach is demonstrated across multiple types of measurement objects, including both artificial and biological samples. All results show a significant reduction in noise as well as enhanced resolution. Structure distinguishability is also increased, which plays a crucial role in tomography applications. In summary, the proposed enhancement method substantially improves image quality. This is achieved by still using the same initial measurement data, but incorporating prior knowledge and maximizing the amount of extracted information. Although initially designed for LOCT systems, the processing steps have potential for broader application in other types of optical coherence tomography and imaging systems.",
keywords = "biomedical imaging, deconvolution, filtering, Optical coherence tomography, signal processing",
author = "Damian Mendroch and Niklas Bauer and David Harings and Alexander Heisterkamp",
note = "Publisher Copyright: {\textcopyright} 2024 SPIE.; SPIE Photonics Europe 2024 : Advances in Ultrafast Condensed Phase Physics IV ; Conference date: 07-04-2024 Through 11-04-2024",
year = "2024",
doi = "10.1117/12.3016987",
language = "English",
series = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "SPIE",
editor = "Jurgen Popp and Csilla Gergely",
booktitle = "Biomedical Spectroscopy, Microscopy, and Imaging III",
address = "United States",

}

Download

TY - GEN

T1 - Deconvolution-based image enhancement for optical coherence tomography

AU - Mendroch, Damian

AU - Bauer, Niklas

AU - Harings, David

AU - Heisterkamp, Alexander

N1 - Publisher Copyright: © 2024 SPIE.

PY - 2024

Y1 - 2024

N2 - This work focuses on enhancing the quality of A- and B-scans of a novel linear optical coherence tomography system (LOCT), addressing the image degradation caused by noise and the blurring characteristics of the system’s three-dimensional point spread function. The enhancement procedure includes an initial spatial and frequency-based pre-filtering that is applied to the measured interference pattern. Subsequently, a more robust envelope detection technique based on the Hilbert transform is employed. Lastly, image structures are reconstructed using a deconvolution algorithm based on maximum likelihood estimation, tailored to meet our unique requirements by adapting it to Rician distributed intensity values and employing a sparseness regularization term. For the deconvolution, both the lateral and axial blur of the system are considered. Emphasis is placed on the optimization of signal detection in high-noise regions, while simultaneously preventing image boundary artifacts. The efficacy of this approach is demonstrated across multiple types of measurement objects, including both artificial and biological samples. All results show a significant reduction in noise as well as enhanced resolution. Structure distinguishability is also increased, which plays a crucial role in tomography applications. In summary, the proposed enhancement method substantially improves image quality. This is achieved by still using the same initial measurement data, but incorporating prior knowledge and maximizing the amount of extracted information. Although initially designed for LOCT systems, the processing steps have potential for broader application in other types of optical coherence tomography and imaging systems.

AB - This work focuses on enhancing the quality of A- and B-scans of a novel linear optical coherence tomography system (LOCT), addressing the image degradation caused by noise and the blurring characteristics of the system’s three-dimensional point spread function. The enhancement procedure includes an initial spatial and frequency-based pre-filtering that is applied to the measured interference pattern. Subsequently, a more robust envelope detection technique based on the Hilbert transform is employed. Lastly, image structures are reconstructed using a deconvolution algorithm based on maximum likelihood estimation, tailored to meet our unique requirements by adapting it to Rician distributed intensity values and employing a sparseness regularization term. For the deconvolution, both the lateral and axial blur of the system are considered. Emphasis is placed on the optimization of signal detection in high-noise regions, while simultaneously preventing image boundary artifacts. The efficacy of this approach is demonstrated across multiple types of measurement objects, including both artificial and biological samples. All results show a significant reduction in noise as well as enhanced resolution. Structure distinguishability is also increased, which plays a crucial role in tomography applications. In summary, the proposed enhancement method substantially improves image quality. This is achieved by still using the same initial measurement data, but incorporating prior knowledge and maximizing the amount of extracted information. Although initially designed for LOCT systems, the processing steps have potential for broader application in other types of optical coherence tomography and imaging systems.

KW - biomedical imaging

KW - deconvolution

KW - filtering

KW - Optical coherence tomography

KW - signal processing

UR - http://www.scopus.com/inward/record.url?scp=85198957561&partnerID=8YFLogxK

U2 - 10.1117/12.3016987

DO - 10.1117/12.3016987

M3 - Conference contribution

AN - SCOPUS:85198957561

T3 - Proceedings of SPIE - The International Society for Optical Engineering

BT - Biomedical Spectroscopy, Microscopy, and Imaging III

A2 - Popp, Jurgen

A2 - Gergely, Csilla

PB - SPIE

T2 - SPIE Photonics Europe 2024

Y2 - 7 April 2024 through 11 April 2024

ER -