Conducted emission of synchronous generators and its dependence on design features

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

  • K. Brune
  • H. O. Seinsch
  • J. Steinbrink

Externe Organisationen

  • Technische Universität Darmstadt
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)71-81
Seitenumfang11
FachzeitschriftElectrical engineering
Jahrgang85
Ausgabenummer2
PublikationsstatusVeröffentlicht - Mai 2003

Abstract

The harmonic content of the no-load voltage of synchronous generators is limited by the requirements of IEC 60034-1. Since the use of analogous telephone systems has diminished, the term telephone harmonic factor (THF) will be replaced by total harmonic distortion (THD) with changed limiting values. This paper deals with the calculation of the time characteristic of the induced voltage and its harmonic content for salient-pole and cylindrical rotor synchronous machines. The influences of skewing, slotting, pole-shoe shaping and the type of the stator winding (integral or fractional slot winding) are especially considered.

ASJC Scopus Sachgebiete

Zitieren

Conducted emission of synchronous generators and its dependence on design features. / Brune, K.; Seinsch, H. O.; Steinbrink, J.
in: Electrical engineering, Jahrgang 85, Nr. 2, 05.2003, S. 71-81.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Brune K, Seinsch HO, Steinbrink J. Conducted emission of synchronous generators and its dependence on design features. Electrical engineering. 2003 Mai;85(2):71-81. doi: 10.1007/s00202-002-0149-z
Brune, K. ; Seinsch, H. O. ; Steinbrink, J. / Conducted emission of synchronous generators and its dependence on design features. in: Electrical engineering. 2003 ; Jahrgang 85, Nr. 2. S. 71-81.
Download
@article{0a85979430474729a2303145e3b5a314,
title = "Conducted emission of synchronous generators and its dependence on design features",
abstract = "The harmonic content of the no-load voltage of synchronous generators is limited by the requirements of IEC 60034-1. Since the use of analogous telephone systems has diminished, the term telephone harmonic factor (THF) will be replaced by total harmonic distortion (THD) with changed limiting values. This paper deals with the calculation of the time characteristic of the induced voltage and its harmonic content for salient-pole and cylindrical rotor synchronous machines. The influences of skewing, slotting, pole-shoe shaping and the type of the stator winding (integral or fractional slot winding) are especially considered.",
keywords = "Harmonic content, Synchronous generators, Telephone harmonic factor, Total harmonic distortion, Waveform of voltage",
author = "K. Brune and Seinsch, {H. O.} and J. Steinbrink",
year = "2003",
month = may,
doi = "10.1007/s00202-002-0149-z",
language = "English",
volume = "85",
pages = "71--81",
journal = "Electrical engineering",
issn = "0948-7921",
publisher = "Springer Verlag",
number = "2",

}

Download

TY - JOUR

T1 - Conducted emission of synchronous generators and its dependence on design features

AU - Brune, K.

AU - Seinsch, H. O.

AU - Steinbrink, J.

PY - 2003/5

Y1 - 2003/5

N2 - The harmonic content of the no-load voltage of synchronous generators is limited by the requirements of IEC 60034-1. Since the use of analogous telephone systems has diminished, the term telephone harmonic factor (THF) will be replaced by total harmonic distortion (THD) with changed limiting values. This paper deals with the calculation of the time characteristic of the induced voltage and its harmonic content for salient-pole and cylindrical rotor synchronous machines. The influences of skewing, slotting, pole-shoe shaping and the type of the stator winding (integral or fractional slot winding) are especially considered.

AB - The harmonic content of the no-load voltage of synchronous generators is limited by the requirements of IEC 60034-1. Since the use of analogous telephone systems has diminished, the term telephone harmonic factor (THF) will be replaced by total harmonic distortion (THD) with changed limiting values. This paper deals with the calculation of the time characteristic of the induced voltage and its harmonic content for salient-pole and cylindrical rotor synchronous machines. The influences of skewing, slotting, pole-shoe shaping and the type of the stator winding (integral or fractional slot winding) are especially considered.

KW - Harmonic content

KW - Synchronous generators

KW - Telephone harmonic factor

KW - Total harmonic distortion

KW - Waveform of voltage

UR - http://www.scopus.com/inward/record.url?scp=0038046242&partnerID=8YFLogxK

U2 - 10.1007/s00202-002-0149-z

DO - 10.1007/s00202-002-0149-z

M3 - Article

AN - SCOPUS:0038046242

VL - 85

SP - 71

EP - 81

JO - Electrical engineering

JF - Electrical engineering

SN - 0948-7921

IS - 2

ER -