Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 71-81 |
Seitenumfang | 11 |
Fachzeitschrift | Electrical engineering |
Jahrgang | 85 |
Ausgabenummer | 2 |
Publikationsstatus | Veröffentlicht - Mai 2003 |
Abstract
The harmonic content of the no-load voltage of synchronous generators is limited by the requirements of IEC 60034-1. Since the use of analogous telephone systems has diminished, the term telephone harmonic factor (THF) will be replaced by total harmonic distortion (THD) with changed limiting values. This paper deals with the calculation of the time characteristic of the induced voltage and its harmonic content for salient-pole and cylindrical rotor synchronous machines. The influences of skewing, slotting, pole-shoe shaping and the type of the stator winding (integral or fractional slot winding) are especially considered.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
- Mathematik (insg.)
- Angewandte Mathematik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Electrical engineering, Jahrgang 85, Nr. 2, 05.2003, S. 71-81.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Conducted emission of synchronous generators and its dependence on design features
AU - Brune, K.
AU - Seinsch, H. O.
AU - Steinbrink, J.
PY - 2003/5
Y1 - 2003/5
N2 - The harmonic content of the no-load voltage of synchronous generators is limited by the requirements of IEC 60034-1. Since the use of analogous telephone systems has diminished, the term telephone harmonic factor (THF) will be replaced by total harmonic distortion (THD) with changed limiting values. This paper deals with the calculation of the time characteristic of the induced voltage and its harmonic content for salient-pole and cylindrical rotor synchronous machines. The influences of skewing, slotting, pole-shoe shaping and the type of the stator winding (integral or fractional slot winding) are especially considered.
AB - The harmonic content of the no-load voltage of synchronous generators is limited by the requirements of IEC 60034-1. Since the use of analogous telephone systems has diminished, the term telephone harmonic factor (THF) will be replaced by total harmonic distortion (THD) with changed limiting values. This paper deals with the calculation of the time characteristic of the induced voltage and its harmonic content for salient-pole and cylindrical rotor synchronous machines. The influences of skewing, slotting, pole-shoe shaping and the type of the stator winding (integral or fractional slot winding) are especially considered.
KW - Harmonic content
KW - Synchronous generators
KW - Telephone harmonic factor
KW - Total harmonic distortion
KW - Waveform of voltage
UR - http://www.scopus.com/inward/record.url?scp=0038046242&partnerID=8YFLogxK
U2 - 10.1007/s00202-002-0149-z
DO - 10.1007/s00202-002-0149-z
M3 - Article
AN - SCOPUS:0038046242
VL - 85
SP - 71
EP - 81
JO - Electrical engineering
JF - Electrical engineering
SN - 0948-7921
IS - 2
ER -