Comparing operational flexibility and performance of pumped hydro energy storage systems: A quantitative analysis of technology options

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer101473
FachzeitschriftEnergy Conversion and Management: X
Jahrgang29
Frühes Online-Datum18 Dez. 2025
PublikationsstatusVeröffentlicht - Jan. 2026

Abstract

This work compares the operational flexibility, energy capacity and efficiency of four standard pumped hydro storage configurations in a 100 MW and 10 h system. The analysis applies two technology options for enhanced flexibility to these configurations: variable-speed operation and hydraulic short circuit (HSC). To simulate system behaviour, a detailed physical model is developed that captures off-design performance, dynamic head variation, and is validated with original equipment manufacturer data. Variable speed enables an operating window around the pump's nominal charging power with limited efficiency penalties, increasing operating-range coverage from 31.5% to 50.5% in a single binary set. HSC operation enables flexibility in deep part-load charging; the operating-range coverage rises from 33.8% to 55.1% in a single ternary set and to 89% in two ternary sets compared with 42.3% without HSC. HSC system efficiency is much lower due to counter-acting power flows and can reach zero even while the individual component efficiencies remain high. Ragone plot analysis is used to quantify the energy capacity at different power levels and shows that high-power HSC charging is prematurely terminated by turbine flow constraints. Advanced flexibility combinations of variable speed and HSC demonstrate potential since their characteristics complement each other, increasing the operating range from 42.2% to 71.8% in the single binary machine set configuration.

Zitieren

Comparing operational flexibility and performance of pumped hydro energy storage systems: A quantitative analysis of technology options. / Beyers, Inga; Krebeck, Lukas; Bensmann, Astrid et al.
in: Energy Conversion and Management: X, Jahrgang 29, 101473, 01.2026.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Beyers I, Krebeck L, Bensmann A, Hanke-Rauschenbach R. Comparing operational flexibility and performance of pumped hydro energy storage systems: A quantitative analysis of technology options. Energy Conversion and Management: X. 2026 Jan;29:101473. Epub 2025 Dez 18. doi: 10.1016/j.ecmx.2025.101473
Beyers, Inga ; Krebeck, Lukas ; Bensmann, Astrid et al. / Comparing operational flexibility and performance of pumped hydro energy storage systems : A quantitative analysis of technology options. in: Energy Conversion and Management: X. 2026 ; Jahrgang 29.
Download
@article{4e3cc047db0045d599787fc1dbb706da,
title = "Comparing operational flexibility and performance of pumped hydro energy storage systems: A quantitative analysis of technology options",
abstract = "This work compares the operational flexibility, energy capacity and efficiency of four standard pumped hydro storage configurations in a 100 MW and 10 h system. The analysis applies two technology options for enhanced flexibility to these configurations: variable-speed operation and hydraulic short circuit (HSC). To simulate system behaviour, a detailed physical model is developed that captures off-design performance, dynamic head variation, and is validated with original equipment manufacturer data. Variable speed enables an operating window around the pump's nominal charging power with limited efficiency penalties, increasing operating-range coverage from 31.5% to 50.5% in a single binary set. HSC operation enables flexibility in deep part-load charging; the operating-range coverage rises from 33.8% to 55.1% in a single ternary set and to 89% in two ternary sets compared with 42.3% without HSC. HSC system efficiency is much lower due to counter-acting power flows and can reach zero even while the individual component efficiencies remain high. Ragone plot analysis is used to quantify the energy capacity at different power levels and shows that high-power HSC charging is prematurely terminated by turbine flow constraints. Advanced flexibility combinations of variable speed and HSC demonstrate potential since their characteristics complement each other, increasing the operating range from 42.2% to 71.8% in the single binary machine set configuration.",
keywords = "Efficiency, Energy-power relations, Hydraulic short circuit, Off-design performance, Pumped hydro energy storage, Variable speed",
author = "Inga Beyers and Lukas Krebeck and Astrid Bensmann and Richard Hanke-Rauschenbach",
note = "Publisher Copyright: {\textcopyright} 2025 The Authors",
year = "2026",
month = jan,
doi = "10.1016/j.ecmx.2025.101473",
language = "English",
volume = "29",

}

Download

TY - JOUR

T1 - Comparing operational flexibility and performance of pumped hydro energy storage systems

T2 - A quantitative analysis of technology options

AU - Beyers, Inga

AU - Krebeck, Lukas

AU - Bensmann, Astrid

AU - Hanke-Rauschenbach, Richard

N1 - Publisher Copyright: © 2025 The Authors

PY - 2026/1

Y1 - 2026/1

N2 - This work compares the operational flexibility, energy capacity and efficiency of four standard pumped hydro storage configurations in a 100 MW and 10 h system. The analysis applies two technology options for enhanced flexibility to these configurations: variable-speed operation and hydraulic short circuit (HSC). To simulate system behaviour, a detailed physical model is developed that captures off-design performance, dynamic head variation, and is validated with original equipment manufacturer data. Variable speed enables an operating window around the pump's nominal charging power with limited efficiency penalties, increasing operating-range coverage from 31.5% to 50.5% in a single binary set. HSC operation enables flexibility in deep part-load charging; the operating-range coverage rises from 33.8% to 55.1% in a single ternary set and to 89% in two ternary sets compared with 42.3% without HSC. HSC system efficiency is much lower due to counter-acting power flows and can reach zero even while the individual component efficiencies remain high. Ragone plot analysis is used to quantify the energy capacity at different power levels and shows that high-power HSC charging is prematurely terminated by turbine flow constraints. Advanced flexibility combinations of variable speed and HSC demonstrate potential since their characteristics complement each other, increasing the operating range from 42.2% to 71.8% in the single binary machine set configuration.

AB - This work compares the operational flexibility, energy capacity and efficiency of four standard pumped hydro storage configurations in a 100 MW and 10 h system. The analysis applies two technology options for enhanced flexibility to these configurations: variable-speed operation and hydraulic short circuit (HSC). To simulate system behaviour, a detailed physical model is developed that captures off-design performance, dynamic head variation, and is validated with original equipment manufacturer data. Variable speed enables an operating window around the pump's nominal charging power with limited efficiency penalties, increasing operating-range coverage from 31.5% to 50.5% in a single binary set. HSC operation enables flexibility in deep part-load charging; the operating-range coverage rises from 33.8% to 55.1% in a single ternary set and to 89% in two ternary sets compared with 42.3% without HSC. HSC system efficiency is much lower due to counter-acting power flows and can reach zero even while the individual component efficiencies remain high. Ragone plot analysis is used to quantify the energy capacity at different power levels and shows that high-power HSC charging is prematurely terminated by turbine flow constraints. Advanced flexibility combinations of variable speed and HSC demonstrate potential since their characteristics complement each other, increasing the operating range from 42.2% to 71.8% in the single binary machine set configuration.

KW - Efficiency

KW - Energy-power relations

KW - Hydraulic short circuit

KW - Off-design performance

KW - Pumped hydro energy storage

KW - Variable speed

UR - http://www.scopus.com/inward/record.url?scp=105027150093&partnerID=8YFLogxK

U2 - 10.1016/j.ecmx.2025.101473

DO - 10.1016/j.ecmx.2025.101473

M3 - Article

AN - SCOPUS:105027150093

VL - 29

JO - Energy Conversion and Management: X

JF - Energy Conversion and Management: X

SN - 2590-1745

M1 - 101473

ER -