2.70 μm CrEr: YSGG laser with high output energy and FTIR-Q-switch

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

  • A. Högele
  • G. Hörbe
  • H. Lubatschowski
  • H. Welling
  • W. Ertmer

Organisationseinheiten

Externe Organisationen

  • Laser Zentrum Hannover e.V. (LZH)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)90-94
Seitenumfang5
FachzeitschriftOptics communications
Jahrgang125
Ausgabenummer1-3
PublikationsstatusVeröffentlicht - 1 Apr. 1996

Abstract

We report on efficient operation of a flashlamp pumped CrEr: YSGG laser at the wavelength of 2.70 μm. A free running output pulse energy of more than 0.6 J at a slope efficiency of 0.36% has been achieved by using a specially-designed low-loss dispersive resonator. We will also report on efficient frustrated total internal reflection (FTIR) Q-switching of this laser. The wavelength of 2.70 μm is of particular interest for laser surgery because of its considerably better transmittance in fused silica fibers compared to well developed 2.79 μm CrEr: YSGG and 2.94 μm Er: YAG lasers.

ASJC Scopus Sachgebiete

Zitieren

2.70 μm CrEr: YSGG laser with high output energy and FTIR-Q-switch. / Högele, A.; Hörbe, G.; Lubatschowski, H. et al.
in: Optics communications, Jahrgang 125, Nr. 1-3, 01.04.1996, S. 90-94.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Högele, A, Hörbe, G, Lubatschowski, H, Welling, H & Ertmer, W 1996, '2.70 μm CrEr: YSGG laser with high output energy and FTIR-Q-switch', Optics communications, Jg. 125, Nr. 1-3, S. 90-94. https://doi.org/10.1016/0030-4018(95)00728-8
Högele, A., Hörbe, G., Lubatschowski, H., Welling, H., & Ertmer, W. (1996). 2.70 μm CrEr: YSGG laser with high output energy and FTIR-Q-switch. Optics communications, 125(1-3), 90-94. https://doi.org/10.1016/0030-4018(95)00728-8
Högele A, Hörbe G, Lubatschowski H, Welling H, Ertmer W. 2.70 μm CrEr: YSGG laser with high output energy and FTIR-Q-switch. Optics communications. 1996 Apr 1;125(1-3):90-94. doi: 10.1016/0030-4018(95)00728-8
Högele, A. ; Hörbe, G. ; Lubatschowski, H. et al. / 2.70 μm CrEr : YSGG laser with high output energy and FTIR-Q-switch. in: Optics communications. 1996 ; Jahrgang 125, Nr. 1-3. S. 90-94.
Download
@article{1ccf32790d294ef0b9a85e4ebf6e88b1,
title = "2.70 μm CrEr: YSGG laser with high output energy and FTIR-Q-switch",
abstract = "We report on efficient operation of a flashlamp pumped CrEr: YSGG laser at the wavelength of 2.70 μm. A free running output pulse energy of more than 0.6 J at a slope efficiency of 0.36% has been achieved by using a specially-designed low-loss dispersive resonator. We will also report on efficient frustrated total internal reflection (FTIR) Q-switching of this laser. The wavelength of 2.70 μm is of particular interest for laser surgery because of its considerably better transmittance in fused silica fibers compared to well developed 2.79 μm CrEr: YSGG and 2.94 μm Er: YAG lasers.",
keywords = "CrEr: YSGG laser, FTIR Q-switch",
author = "A. H{\"o}gele and G. H{\"o}rbe and H. Lubatschowski and H. Welling and W. Ertmer",
year = "1996",
month = apr,
day = "1",
doi = "10.1016/0030-4018(95)00728-8",
language = "English",
volume = "125",
pages = "90--94",
journal = "Optics communications",
issn = "0030-4018",
publisher = "Elsevier",
number = "1-3",

}

Download

TY - JOUR

T1 - 2.70 μm CrEr

T2 - YSGG laser with high output energy and FTIR-Q-switch

AU - Högele, A.

AU - Hörbe, G.

AU - Lubatschowski, H.

AU - Welling, H.

AU - Ertmer, W.

PY - 1996/4/1

Y1 - 1996/4/1

N2 - We report on efficient operation of a flashlamp pumped CrEr: YSGG laser at the wavelength of 2.70 μm. A free running output pulse energy of more than 0.6 J at a slope efficiency of 0.36% has been achieved by using a specially-designed low-loss dispersive resonator. We will also report on efficient frustrated total internal reflection (FTIR) Q-switching of this laser. The wavelength of 2.70 μm is of particular interest for laser surgery because of its considerably better transmittance in fused silica fibers compared to well developed 2.79 μm CrEr: YSGG and 2.94 μm Er: YAG lasers.

AB - We report on efficient operation of a flashlamp pumped CrEr: YSGG laser at the wavelength of 2.70 μm. A free running output pulse energy of more than 0.6 J at a slope efficiency of 0.36% has been achieved by using a specially-designed low-loss dispersive resonator. We will also report on efficient frustrated total internal reflection (FTIR) Q-switching of this laser. The wavelength of 2.70 μm is of particular interest for laser surgery because of its considerably better transmittance in fused silica fibers compared to well developed 2.79 μm CrEr: YSGG and 2.94 μm Er: YAG lasers.

KW - CrEr: YSGG laser

KW - FTIR Q-switch

UR - http://www.scopus.com/inward/record.url?scp=0030125739&partnerID=8YFLogxK

U2 - 10.1016/0030-4018(95)00728-8

DO - 10.1016/0030-4018(95)00728-8

M3 - Article

AN - SCOPUS:0030125739

VL - 125

SP - 90

EP - 94

JO - Optics communications

JF - Optics communications

SN - 0030-4018

IS - 1-3

ER -