Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 90-94 |
Seitenumfang | 5 |
Fachzeitschrift | Optics communications |
Jahrgang | 125 |
Ausgabenummer | 1-3 |
Publikationsstatus | Veröffentlicht - 1 Apr. 1996 |
Abstract
We report on efficient operation of a flashlamp pumped CrEr: YSGG laser at the wavelength of 2.70 μm. A free running output pulse energy of more than 0.6 J at a slope efficiency of 0.36% has been achieved by using a specially-designed low-loss dispersive resonator. We will also report on efficient frustrated total internal reflection (FTIR) Q-switching of this laser. The wavelength of 2.70 μm is of particular interest for laser surgery because of its considerably better transmittance in fused silica fibers compared to well developed 2.79 μm CrEr: YSGG and 2.94 μm Er: YAG lasers.
ASJC Scopus Sachgebiete
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
- Physik und Astronomie (insg.)
- Atom- und Molekularphysik sowie Optik
- Chemie (insg.)
- Physikalische und Theoretische Chemie
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Optics communications, Jahrgang 125, Nr. 1-3, 01.04.1996, S. 90-94.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - 2.70 μm CrEr
T2 - YSGG laser with high output energy and FTIR-Q-switch
AU - Högele, A.
AU - Hörbe, G.
AU - Lubatschowski, H.
AU - Welling, H.
AU - Ertmer, W.
PY - 1996/4/1
Y1 - 1996/4/1
N2 - We report on efficient operation of a flashlamp pumped CrEr: YSGG laser at the wavelength of 2.70 μm. A free running output pulse energy of more than 0.6 J at a slope efficiency of 0.36% has been achieved by using a specially-designed low-loss dispersive resonator. We will also report on efficient frustrated total internal reflection (FTIR) Q-switching of this laser. The wavelength of 2.70 μm is of particular interest for laser surgery because of its considerably better transmittance in fused silica fibers compared to well developed 2.79 μm CrEr: YSGG and 2.94 μm Er: YAG lasers.
AB - We report on efficient operation of a flashlamp pumped CrEr: YSGG laser at the wavelength of 2.70 μm. A free running output pulse energy of more than 0.6 J at a slope efficiency of 0.36% has been achieved by using a specially-designed low-loss dispersive resonator. We will also report on efficient frustrated total internal reflection (FTIR) Q-switching of this laser. The wavelength of 2.70 μm is of particular interest for laser surgery because of its considerably better transmittance in fused silica fibers compared to well developed 2.79 μm CrEr: YSGG and 2.94 μm Er: YAG lasers.
KW - CrEr: YSGG laser
KW - FTIR Q-switch
UR - http://www.scopus.com/inward/record.url?scp=0030125739&partnerID=8YFLogxK
U2 - 10.1016/0030-4018(95)00728-8
DO - 10.1016/0030-4018(95)00728-8
M3 - Article
AN - SCOPUS:0030125739
VL - 125
SP - 90
EP - 94
JO - Optics communications
JF - Optics communications
SN - 0030-4018
IS - 1-3
ER -